Lasko FHV820 37.7 Inches Oscillating Hybrid Fan And Space Heater

INSTRUCTION MANUAL - Page 2

For FHV820.

PDF File Manual, 8 pages, Read Online | Download pdf file

FHV820 photo
Loading ...
NEW 5/21 2 FHV820ES
SAVE THESE INSTRUCTIONS
Read all instructions before using this Unit.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, these instructions and warnings should always be
followed to reduce the risk of fire, electrical shock and injury to persons:
CAUTION
Always place the Unit on a stable, flat, level surface when operating, to avoid the chance of the Unit overturning. Locate the Power Cord so the Unit or other
objects are not resting on it. DO NOT run Power Cord under carpeting. DO NOT cover Power Cord with throw rugs, runners, or similar coverings as this may
cause cord to overheat. Arrange Power Cord away from room traffic and where it will not be tripped over.
This Unit is HOT when in use. To avoid burns, do not let bare skin touch hot surfaces. Always use handle when moving this Unit. Keep combustible materials, such as
furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (0.9 m) from the front of the Unit and keep them at least 1 foot (0.3 m) from the sides and rear.
This Unit is not intended for use in wet or damp locations. This Unit is not intended for use in bathrooms, laundry areas and similar indoor locations. NEVER locate
a Unit where it may fall into a bathtub or other water container.
DO NOT use Unit outdoors.
This Unit is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric
Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings. THIS UNIT DOES
NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).
This Unit is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards
relating to electrical requirements for Hazardous locations. THIS UNIT DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).
Remote controls for other appliances or electronic equipment can sometimes interfere with the operation of this Unit. If this occurs, move the Unit to another location.
Keep Unit remote control unit away from chairs and your bed where it may be sat or laid upon and inadvertently turn on the Unit.
WARNING
WARNING
PLUG UNITS DIRECTLY INTO A 120V WALL OUTLET/RECEPTACLE ONLY. NEVER USE WITH AN EXTENSION CORD. DO NOT PLUG UNIT INTO
ANY OTHER CORD CONNECTED DEVICE, SUCH AS A POWER STRIP, SURGE PROTECTOR, MULTIPLE OUTLET ADAPTER, CORD REEL OR
OUTLET-TYPE AIR FRESHENER. THE USE OF SUCH DEVICES MAY CREATE A FIRE HAZARD. DO NOT PLUG MULTIPLE DEVICES IN THE SAME
OUTLET OR ON SAME CIRCUIT AS UNIT.
FAULTY WALL OUTLET CONNECTIONS MAY CAUSE THE WALL OUTLET TO OVERHEAT. BE SURE THAT UNIT PLUG FITS TIGHTLY INTO OUTLET
BEFORE EACH USE. DURING USE, CHECK TO MAKE CERTAIN THE UNIT PLUG IS NOT OVERHEATING. IF NECESSARY HAVE A QUALIFIED
ELECTRICIAN CHECK AND/OR REPLACE THE WALL OUTLET. DO NOT USE THIS UNIT WITH ANY SOLID STATE SPEED CONTROL DEVICES.
Make certain that the power source conforms to the electrical requirements of the Unit.
Extreme caution is necessary when any Unit is used by or near children or invalids. The Unit should not be left operating unattended. Never leave
children unattended when the Unit is on or plugged in.
This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized
outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to
defeat this safety feature.
DO NOT use the Unit in areas where gasoline, paint, or flammable liquids are used or stored. DO NOT use Unit in locations where flammable or
explosive chemicals are stored, or in wet atmospheres.
Do not operate any Unit with a damaged cord or plug or after the Unit malfunctions, or has been dropped or damaged in any manner. To disconnect
Unit, turn the Unit OFF then remove the plug from the outlet.
Always unplug Unit when not in use. Unplug power cord before servicing or moving the Unit.
Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock, fire, or damage the
Unit. Do not block or tamper with the Unit in any manner while it is in operation.
Do not block air intakes or exhaust in any manner. Do not place on soft surfaces, like a bed, where openings may become blocked. Do not depend
on the on/off switch as the sole means of disconnecting power when servicing or moving the Unit. Always unplug the power cord.
NEW 5/21 7 FHV820ES
1 Cuerpo
2 Control Remoto
1
Partes Incluidas
2
Limpieza del Filtros
2. Aspire el Filtros cada dos semanas; esto
ayudará a mantener un rendimiento óptimo.
1. Retire la lengüeta del
Filtro de la unidad.
* PARA UNA DESCRIPCIÓN MÁS DETALLADA
DE FUNCIÓN AUTO ECO
, VER PÁGINA 8
Información adicional:
Memoria - Si la unidad se apaga con el botón de encendido, mientras está en el
modo de ventilador o Calefactor, reanudará el funcionamiento en la última config-
uración de velocidad / Calefactor cuando se encienda.
La unidad se atenúa al 80% después de 10 segundos.
Controles
Botón de Temporizador
El temporizador se puede configurar para 8 horas.
Continúe pulsando el Botón del Temporizador para
llegar a la configuración de tiempo deseada. Cuan-
do se activa el botón Temporizador, se iluminará el
color opuesto (depende de Calefacción / Ventilador).
Botón de Oscilación de Base
Presione para Iniciar/Detener la función de
oscilación de la base.
* Botón Auto Eco
(
+
)
Presione para Aumentar la temperatura
ambiente deseada.
* Botón Auto Eco
(-)
Presione para Disminuir la temperatura
ambiente deseada.
Botón de Velocidad del Ventilador
La Velocidad del Ventilador se puede ajustar
a Alta Velocidad (F4), Alta Velocidad (F3),
Velocidad Media (F2), o Velocidad Baja (F1) .
Botón de Modo de Calor
El calor se puede ajustar a
Calor Turbo (H4), Calor Alto (H3)
Calor Medio (H2) o Calor Bajo (H1).
Botón de Encendido del Calefactor
ENCENDIDO/APAGADO el Calefactor
presionando el Botón de Encendido.
Botón de Encendido del Ventilador
ENCENDIDO/APAGADO el Ventilador
presionando el Botón de Encendido.
Cuando la unidad está encendida, comienza una cuenta regresiva de 4 segundos para la inicialización.
Se requiere una cuenta regresiva de 4 segundos al cambiar de modo (Calefactor a Ventilador o Ventilador a Calefactor).
Para apagar el LED de luz ambiental, mantenga presionado
cualquiera de los botones de encendido durante 3 segundos.
3. Use un cepillo de cerdas suaves para aflojar
suavemente cualquier polvo que no haya sido
retirado por la aspiradora. Vuelva a colocar la Filtros.
Loading ...
Loading ...
Loading ...