HOW TO DISPLAY PROBE TEMPERATURES:
STEP 1 - To display T1 temperature, press and release the info button
. “t1” will appear. See image 1.
STEP 2 - Press and hold the info button . This is the temperature of
the T1 Probe. See image 2.
STEP 3 - By releasing the info button , “t2” will appear. Press and hold
the info button to display the temperature of the T2 probe.
STEP 4 - By releasing the info button again, “t3” will appear. Press and
hold the info button to display the temperature of the T3 probe. (If
probe T3 is not activated, “t3” will not appear of the display.)
DISPLAYING TEMPERATURE PROBES, T1, T2, T3:
WHY: To display temperature probe readings in different locations of the cabinet.
DISPLAY CODES
DISPLAY
Defrost in progress Room high temperature alarm
Controller in stand-by Room low temperature alarm
Door open alarm Probe T1 failure
Instant Probe 1 temperature Probe T2 failure
Instant Probe 2 temperature Probe T3 failure
Instant Probe 3 temperature Maximum probe 1 temperature recorded
Minutes of the Real Time Clock Minimum probe 1 temperature recorded
Hours of the Real Time Clock Keypad state lock