CAUTION: In order to avoid a hazard due to inadvertent resetting of the
thermal cut-out, this appliance must not be supplied through an external
switching device, such as a timer, or connected to a circuit that is regularly
switched on and off by the utility.
• This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge, unless they are supervised or have been given instruction
concerning the use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the
appliance.
• If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
WARNING: You must not cover this dehumidifier. Covering this
dehumidifier presents fire risk and will activate the safety fuse; permanently
disabling the unit.
WARNING: Do not use this dehumidifier in small rooms when they are
occupied by persons not capable of leaving the room on their own, unless
constant supervision is provided.
WARNING: To reduce the risk of fire, keep textiles, curtains, or any
flammable material a minimum distance of 1 metre from the air outlet.
General Care and Safety Guide
• Use only the voltage specified on the rating label of the appliance.
• The dehumidifier must not be located immediately below a socket outlet.
• Keep all objects at least 1 metre from the front, sides and rear of the appliance.
• This appliance is intended for household use only and not for commercial or industrial use.
• Indoor use only.
• Use this appliance only as described in this manual. Any other use is not recommended by
the manufacturer and may cause fire, electric shock or injury.
• Do not use the dehumidifier if it has been dropped or damaged.
• The common cause of overheating is deposits of dust or fluff in the appliance. Ensure these
deposits are removed regularly by unplugging the appliance and vacuum cleaning the air
vents and grills.
• Always unplug appliance when not in use.
• When the appliance has been unpacked, check it for transport damage and ensure all parts
have been delivered. If parts are missing or the appliance has been damaged, contact the
Customer Services Team.
• Do not use if there are visible signs of damage to the dehumidifier.
YOUR SAFETY IS IMPORTANT TO US. PLEASE ENSURE YOU TAKE NOTE OF THE
INSTRUCTIONS AND WARNINGS OUTLINED IN THIS MANUAL.

• Never use the appliance to dry clothes.
• Do not connect the appliance to mains supply until completely assembled and adjusted.
• Ensure hands are dry before handling the plug or main unit.
• Ensure dehumidifier is on a flat, stable, heat-resistant surface.
• Do not operate with cord set coiled up as a heat build up is likely, which could be sufficient to
become a hazard.
• Carry out regular checks of the supply cord to ensure no damage is evident
• Do not operate this appliance with a damaged cord, plug or after the appliance malfunctions
or has been dropped or damaged in any manner. Return to a qualified electrical person for
examination, electrical service or repair.
• Do not twist, kink or wrap the cord around the appliance, as this may cause the insulation to
weaken and split. Always ensure that all cord has been removed from any cord storage area
and is unrolled before use.
• It is recommended that this dehumidifier is plugged directly into the wall socket. Power
boards are not rated to supply power to high wattage appliances.
• A correctly specified, undamaged extension cord may be used with this dehumidifier
provided it is used in a safe manner.
• Do not remove plug from power socket until the appliance has been switched off.
• Do not remove plug from power socket by pulling cord; always grip plug.
• Do not place cord under carpet or cover with rugs or furniture. Arrange the cord so it cannot
be tripped over.
• Don’t place appliance on bedding or on thick & long carpet where the openings may get
blocked.
• Switch off and use handle provided when moving
• Do not place appliance close to radiant heat source.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may
cause an electric shock, fire or damage to the appliance.
• Do not sit on the appliance.
• Do not use abrasive cleaning products on this appliance. Clean with a damp cloth (not wet)
rinsed in hot soapy water only. Always remove plug from the mains supply before cleaning.
• Do not operate in areas where petrol, paint or other flammable liquids are used or stored.
• Do not use this appliance in the immediate surrounds of a bath, a shower, or a swimming
pool or other liquids.
• The appliance must not be immersed in any liquids.
• There are no user serviceable parts installed in the unit.
• Do not place the unit in wardrobes or other enclosed spaces as this may cause fire hazards.
• This unit is not supposed to be used in or around locations where foodstuffs, works of art or
delicate articles of science, etc. are stored.
• If your appliance does not work, or is not working properly, contact the place of purchase or
the Customer Services Team.
General Care and Safety Guide

Operating Your Dehumidifier
Always choose a safe location for the dehumidifier, keeping in mind the safety
precautions outlined. Ensure all packaging has been removed from the unit before use.
Please follow the below instructions.
WARNING: In order to avoid overheating or fire, do not cover the
dehumidifier.
WARNING: Keep all objects at least 1 metre from the front and 150mm
from the sides of the appliance.
WARNING: Do not use this dehumidifier with a programmer, separate
timer, remote-control system or any other device that switches the
dehumidifier on automatically, since a fire risk exists if the dehumidifier is
covered or positioned incorrectly.
WARNING:Never leave this dehumidifier unattended.
Ensure dehumidifier is on a flat, stable, heat-resistant surface.
Once the dehumidifier is in a safe operating position and all switches are in the off
position, insert the power plug into the mains outlet.
CAUTION: Ensure the power cord is not tight because if pulled it may
partially pull the plug from the socket. A partially inserted plug will overheat
the plug and socket and could result in fire.
DEHUMIDIFIER CONTROL PANEL

Leave the appliance to stand for one hour after transport or after the unit has been on its side before
connecting it to the mains supply to let the refrigerant settle.
Ensure all external windows and doors are closed before turning on the unit.
Ensure that the water container is positioned correctly.
OPERATION
Plug into power supply and switch on at the mains. When plugged into power socket, 3 beep signals will
be heard.
2. Press the “ON/OFF” button to turn on the unit. The louvre opens automatically and the unit goes into
the default mode of continuous dehumidification and mid speed running.
The LCD display shows the ambient humidity and temperature (the variation of relative humidity can be
5%).
To turn off, press the “ON/OFF” button again; the dehumidifier will stop working and the louvre will
close.
DEHUMIDIFY
Press the key “〈” or “〉”to choose your humidity setting. You can choose the continuous
dehumidification option or your preferred humidity required in the range of 50-70%.
When the machine is set in automatic dehumidification, the desired humidity setting and fan Speed is
indicated on the LCD display.
When ambient humidity is 5% lower than your setting, compressor shuts off and fan works at low speed.
If ambient humidity is 5% higher than the setting, the dehumidification is activated again.
When the machine is set in continuous dehumidification, the continuous dehumidification mode and
corresponding fan speed will be displayed on LCD. In this mode, the ambient humidity has no effect on
the operation of the dehumidifier.
In automatic dehumidification mode (50%RH, 60%RH, 70%RH), or continuous dehumidification mode
press “Speed” to select the fan speed either “Mid speed” or “Low speed”.
When in dry mode, you cannot adjust the humidity setting. You need to come out of the dry mode to set
desired humidity.
SPEED
Press this key to select the fan speed at “mid speed” level or “Low speed”.
In automatic dehumidification mode or continuous dehumidification mode, press “Speed” to select the
fan at “Mid speed” or “Low speed”.
In dry mode, you cannot select the fan mode. It runs in high speed by default.
When in automatic defrost, the fan works at “Mid speed”.
When the sensor detects ambient temperature exceeding 32°C, it automatically moves to “Mid speed”
and when sensor detects ambient temperature lower than 30°C, it returns back to previous speed
setting.
Operating your Appliance

TIMER OFF
When the unit is operating press the TIMER button to set the length of time that you would like the unit
to run for before turning off. Each press of the TIMER button will adjust the length of time by 1 hour
increments from 1 – 24 hours. To turn off the Timer function, set the Timer back to “0” hours or simply
turn the unit off.
TIMER ON
When the unit is Off press the TIMER button to set the length of time that you would like the unit to
remain off before turning on. Each press of the TIMER button will adjust the length of time by 1 hour
increments from 1 – 24 hours. To turn off the Timer function, set the Timer back to “0” hours or simply
turn the unit on manually.
WARNING: Take care in positioning your appliance, using the timer will mean
the unit will come on automatically. Fire may result if placed next to combustible
material.
DRY
Press this key to start or stop dry mode.
Press “dry”, the dry pattern is displayed on LCD, the dehumidifier runs in dry mode and in continuous
dehumidification. The fan works at “high speed “level.
The louver swings automatically press the “swing” button stops the swing function.
SWING
When the dehumidifier runs, press this key to start swing and the louvre oscillates automatically, and
the swing pattern is displayed on LCD. Press this key again and the louvre will stop at that position.
DEFROST
When the dehumidifier works in low temperature, frost will be produced on the surface of evaporator.
To ensure the dehumidifier performs well, the automatic defrost function is designed with the
dehumidifier.
1When the temperature sensor detects the temperature of the evaporator i≤ -1°C,the dehumidifier
moves to defrost mode automatically and after defrosting, it automatically starts dehumidifying.
When defrosting, the red defrost indicator light illuminates.
When defrosting, the compressor will turn off and the fan runs at mid speed.
WATER TANK FULL ALARM
When the water tank is full a buzzer will sound 10 times and the symbol of water full is shown on the
LCD screen, all other symbols disappear. The dehumidifier stops working and louver closes.
Carefully remove the water tank and empty the water, and then reinstate the water tank. The
dehumidifier will start working in the previously set conditions. If you do not reinstate the bucket within
3 minutes, the dehumidification process will start and there may be water spillage. Hence it is
recommended to switch off the dehumidifier completely from the power socket and then remove the
water bucket.
Operating your Appliance

PERMANENT WATER DRAINAGE
It is possible to connect a drainage tube (not supplied) to the appliance for permanent water drainage.
If this option is desired, you will need to purchase a suitable PVC tube from your local hardware retailer
(Goldair does not hold tubes as spare parts).
1. Connect the drainage hose to the drain spout.
2. Place the end of the drainage hose in a drainage outlet. Ensure that the end of the hose is lower
than the drain opening, otherwise the water will not drain and flooding may occur.
3. Also ensure the water tank is positioned in the unit otherwise the continuous drainage will not
operate. It will also catch any overflow.
4. When you no longer wish to use the permanent water drainage, disconnect the drainage tube from
the device and water will be collected in tank again.
Operating your Appliance

Care and Cleaning
CARE AND CLEANING
The appliance requires regular cleaning to ensure trouble free operation:
Unplug the appliance from the mains supply before cleaning.
Ensure that the appliance has been allowed to cool down completely before cleaning.
Use a damp cloth (not wet) to wipe the exterior of the appliance to remove dust and dirt.
Never use solutions such as benzene, thinners or polishing agents.
Use a vacuum cleaner to remove dust and fluff from around the grills and fins.
Ensure the appliance is dry before plugging back into the mains supply.
TO CLEAN THE AIR FILTER:
Unplug the appliance from the mains supply.
Remove the filter. Clean the filter with a vacuum or with water. Dry the filter.
Ensure the filter is completely dry before placing back in the unit.
Never use unit without the air filter.
Do not attempt to dismantle the appliance. There are no user serviceable parts. For service or repair,
contact an authorised electrical service technician.
STORAGE
To store the unit, remove the plug from the socket and empty the water container. Allow the container
and the appliance to dry completely. Clean the air filter. Store the device in a dust-free location,
preferably covered with a sheet of plastic.

Trouble Shooting your Dehumidifier
Goldair – New Zealand
Monday – Friday 8am-5pm
Phone +64 (0)9 917 4000
Phone 0800 232 633
Goldair – Australia
Monday – Friday 8am-5pm
Phone +61 (0)3 9365 5100
Phone 1300 465 324
Problem Cause Solution
The Dehumidifier will not
turn on
The power is not connected
Insert plug into mains power
supply and turn unit on
The Dehumidifier is not
extracting water
The water tank is full
Remove the water tank and
empty water
The water tank is not in its
correct position
Remove water tank and
replace it correct position
The air filter is clogged
Clean the air filter as per
instructions in user manual
The temperature or relative
humidity in the room is too
low
It is normal for the
Dehumidifier not to operate
in low humidity or low
temperatures
The Dehumidifier operates,
but reduces the relative
humidity in the room by
small amounts
The room which the
Dehumidifier is operating in
is too large
Recommend using a
Dehumidifier with a larger
capacity
There are too many sources
of humidity
Recommend using a
Dehumidifier with a larger
capacity
The room has too much
ventilation
Reduce the number of
ventilation sources (i.e. close
windows, doors, etc.
SUPPORT AND TECHNICAL ADVICE
TECHNICAL SPECIFICATION
Model No: GPDH390
Supply: 220-240VAC 50Hz
Wattage: 430W
Unit Capacity: 25.0L/day max (30℃/80%RH)
Tank Capacity: 5.0L
Refrigerant: R134a/145g
PROOF OF PURCHASE
To receive warranty retain receipt as proof of purchase.

Thank you for purchasing this Goldair Platinum product. Your product is warranted against faults and manufacture when used in
normal domestic use for a period of three years. In non-domestic use Goldair limits the voluntary warranty to three months.
Goldair undertake to repair or replace this product at no charge if found to be defective due to a manufacturing fault during the
warranty period.
This warranty excludes damage caused by misuse, neglect, shipping accident, incorrect installation, or work carried out by anyone
other than a qualified electrical service technician.
PLEASE KEEP YOUR RECEIPT AS THIS WILL HELP VERIFY YOUR WARRANTY.
The benefits given to you by this warranty are in addition to other rights and remedies available to you under law in relation to the
goods or services to which this warranty relates.
In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a
replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a
major failure.
In New Zealand this warranty is additional to the conditions and guarantees of the Consumers Guarantee Act (1993).
Three Year Warranty
Goldair Three Year Warranty (IMPORTANT: Please complete and retain this warranty card)
Name
Address
Place Of Purchase Date Of Purchase
Name Of Product Model Number
Attach a copy of the purchase receipt to this warranty card
Due to continual design improvements, the product illustrated in this User Manual may differ slightly from the actual product.
Goldair – New Zealand
CDB Goldair
PO Box 100-707
N.S.M.C
Auckland
Phone +64 (0)9 917 4000
Phone 0800 232 633
www.goldair.co.nz
Goldair – Australia
CDB Goldair Australia Pty
PO Box 574
South Morang
Victoria, 3752
Phone +61 (0)3 9365 5100
Phone 1300 GOLDAIR (1300 465 324)
www.goldair.com.au