Ancona AN-2142 Elite 30 Inch 5 Burner Gas Cooktop

User Manual & Installation Instructions - Page 27

For AN-2142.

PDF File Manual, 31 pages, Read Online | Download pdf file

AN-2142 photo
Loading ...
Loading ...
Loading ...
LP/Propane Gas Conversion
This appliance can be used with Natural Gas or LP/Propane gas. It is shipped from the factory for
use with natural gas. A kit for converting to LP gas is supplied with your cooktop. The kit is marked
"FOR LP/PROPANE GAS CONVERSION".
When the cooktop is converted for liquid pretroleum (LP) gas, the LP gas supply is required to
provide a minimum of 10” to a maximum of 14” water column to the cooktop regulator.
The conversion must be performed by a qualified service technician in accordance with
the kit instructions and all local codes and requirements. Failure to follow instructions could
result in serious injury or property damage. The qualified agency performing this work
assumes responsibility for the conversion.
BURNER TYPE
MAX
OUTPUT
MIN
OUTPUT
Natural Gas
LPG
BTU
BTU
Nozzle
mm
Cons
M
3
/h
Nozzle
mm
Cons
g/h
Auxiliary Burner
5000
1023
1 x 1.10
0.13
1 x 0.70
115
Semi-Rapid Burners
6800
1887
1 x 1.20
0.18
1 x 0.80
150
Rapid Burner
8500
2730
1x 1.45
0.22
1 x 0.91
197
Triple Ring Burner
16000
5119
5 x Φ0.93
0.41
5 x Φ0.56
352
WARNING
Failure to make the appropriate conversion can result in serious personal injury and property
damage.
TOOLS YOU WILL NEED FOR CONVERSION
Wrench
7mm Nut Driver Safety Glasses
Small Flat-head Screwdriver (2 to 2.4 mm or 3/32″ tip size, 60 mm long)
Figure 18
27
Loading ...
Loading ...
Loading ...