Awoco RH-IT08-M30 RH-IT08-M 14-1/2"D Super Quiet Split Insert Stainless Steel Range Hood, 4 Speeds

User Manual - Page 8

For RH-IT08-M30.

PDF File Manual, 16 pages, Read Online | Download pdf file

RH-IT08-M30 photo
Loading ...
Loading ...
Loading ...
8
INSTALLATION
Installing the Blower Unit
Install the mounting brackets to the edges of
the Blower Unit with the screws provided.
Install the Blower Unit onto the lumbers in the
attic.
Route the Speed Control Cord and Duct to the
Blower Unit. Use duct elbows to make turns
only when it's needed. Cut and remove the
excess length when done routing.
Connect the duct to the Blower Unit's vent in
adapter routed from the Hood Unit.
Connect the duct from the Blower Unit's vent
out adapter to the roof or wall vent out.
Connect the Duct from the roof to the vent
opening next to the Black Connection Box.
Use foil tape or duct tape to seal all connections.
Connect the Speed Control Cord from the Hood
Unit to the Connection Box on the Blower Unit.
See Electrical Connection section below for how
to properly connect the wires
.
CAUTION
For safety purpose, please connect a separate
Gound Wire to the Blower Unit Chassis screw.
(
Note, don't connect the Ground wire to Blower
Unit's Green Speed Wire!!!)
Important
If you have an
Awoco Exterior Blower Unit, or any
Blower Unit from other Brands
:
DO NOT
CONNECT
the wires as shown in the
Wiring Diagram. Any damage from false wiring is
not covered by the warranty.
Refer to your Blower Unit's USER MANUAL
for
how to properly connect the wires.
Electrical Connection
Connecting
the
Blower Unit
to the
Hood Unit
is as
simple as "
Match Colors and Connect
":
Simply pick the wires with the same color from
both ends and secure them with a wire nut
connector
. (Refer to the Wiring Diagram in the Test
Run section for how to connect the wires properly.)
This range hood comes with a power cord with
a 3-prong plug. Connect the power cord to a
designated grounded standard 110V outlet.
Warning
Before Plugging the Power Cord to the Outlet:
Make sure all wires are connected properly between
the Hood Unit and the Blower Unit.
Insolate any spare wires with electrical tape to prevent
them from touching each other which will result in a
short circuit.
Electrical Shock Hazard
Disconnect power before
servicing
In case of a direct connection to the house wiring is
preferred, do the following:
Disconnect the power.
Cut off the plug from the power cord.
Connect the wires from the power cord to the
wires from the house wiring using UL listed
wire connectors.
Store the excess wires in the wiring box.
Reconnect the power.
Installing the Baffle Filters
Peel off the protective film from the baffle filters if
there's any:
Soak the Baffle Filters into hot waters or use
heated air from a hair dryer to soften the films.
Peel off the films from the corner.
Align the baffle filters with the Hood Unit and install
them from left to right.
Completing the Installation
Turn power ON in the control panel. Check all lights and
fan operations.