1. Prepare the Site
WARNING: Risk of electric shock, fire, or personal injury.
This product must be grounded and connected only to a
dedicated, nominal 120 VAC, 60 Hz circuit protected by a
minimum 15 A Ground-Fault Circuit-Interrupter (GFCI) or
Residual Current Device (RCD).
If applicable, remove the existing toilet seat.
Turn off the water supply to the toilet.
Flush the toilet to relieve any pressure from the water supply
hose.
Disconnect the water supply hose from the toilet fill valve.
Use a pencil to mark the remote control installation location on
the wall.
Install an Electrical Outlet
Determine the electrical outlet location. Locate the electrical outlet
within 12 (305 mm) of the toilet.
IMPORTANT! Do not plug the seat into the electrical outlet at this
time.
Install and ground the electrical outlet. This electrical outlet must
be a dedicated, nominal 120 VAC, 60 Hz circuit protected by a
minimum 15 A Ground-Fault Circuit-Interrupter (GFCI) or
Residual Current Device (RCD).
36"
(914 mm)
38" (965 mm) - 66" (1676 mm)
1321454-2-A 4 Kohler Co.