16" (406mm) On Center Gauge (Fig. 8)
16" (406mm) on center gauge helps to indicate stud location.
1. Pull up the on center gauge to rotate to the opposite side.
2. Press on the on center gauge to snap into the magazine.
3. 16" (406mm) is measured from nose to the tip of O.C. gauge to
help find stud.
FIG. 8
16" (406mm)
Cold Weather Operation
WARNING: Read the section titled Important Safety Instructions
at the beginning of this manual. Always wear eye and ear protection
when operating this tool. Keep the nailer pointed away from yourself
and others. For safe operation, complete the following procedures
and checks before each use of the nailer.
When operating tools at temperatures below freezing, complete
preparation procedures outlined above and follow the directions
below.
1. Make sure compressor tanks have been properly drained prior
to use. Always drain the compressor tanks at least once daily
while using the nailer. This is especially important in cold weather
because any moisture in the air in the tanks will condense in the
cold temperature.
2. Keep the tool as warm as possible prior to use.
3. Lower air pressure to 80 psi or less.
4. Actuate the tool 5 or 6 times into scrap lumber to lubricate o-rings.
5. Turn pressure up to operating level (not to exceed 120 psi) and
use tool as normal.
Hot Weather Operation
Tool should operate normally. However, keep tool out of direct sunlight
as excessive heat can damage bumpers, o-rings and other rubber
parts.
MAINTENANCE
WARNING: Disconnect air line from tool and remove fasteners
from magazine before making adjustments or personal injury may
result.
Clearing a Jammed Fastener (Fig. 1, 9)
If a fastener becomes jammed in the nosepiece, keep the tool pointed
away from you and follow these instructions to clear:
1. Disconnect the tool from the air supply.
2. Release the pusher (G) so it is no longer applying force to the nail
sticks.
3. Open the jam clearing nose door by pulling down and then up on
the latch. (C)
4. Remove the jammed fastener. In certain circumstances, pliers
may be required to remove the fastener.
5. Close the jam clearing nose door latch.
6. Pull nail pusher back behind nail sticks.
7. Perform tool operation check.
NOTE: Should fasteners continue to jam frequently in nosepiece,
have tool serviced by an authorized DEWALT service center.