Waldorf RNB8100G-LS Bold 900mm Gas Target Top Leg Stand

Installation Operation Manual - Page 6

For RNB8100G-LS.

PDF File Manual, 30 pages, Read Online | Download pdf file

RNB8100G-LS photo
Loading ...
Loading ...
Loading ...
4
- All Other Markets:
(*) Measure burner operating pressure at target top hob manifold test point with target top burner (Inner and
outer ring) operating at full setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, apart from when
converting between gasses, if required.
(**) TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas regulator supplied.
Town Gas Option is only available with specific ex-factory built Town Gas models, which can also be
converted to any other gas. Standard models can only be converted between Nat. Gas, LP Gas and Butane,
but not Town Gas.
Refer to Gas Conversion and Specifications' section of this manual for further details.
Bench Models Only.
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
55mm from floor and is entered from beneath appliance. An optional underside connection is
available.
Cabinet and Refrigeration Base Only.
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
655mm from floor and is entered from beneath appliance. An optional underside connection is
available.
Connection is ¾ BSP male.
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 1.0 kPa 0.63 kPa
Gas Connection ¾BSP Male
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr
Supply Pressure 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 2.6 kPa 2.6 kPa
Gas Connection ¾BSP Male
Loading ...
Loading ...
Loading ...