Klein CL700 Tools Autoranging Digital Clamp Meter, TRMS 600Amp, AC/DC Volts, Current, LoZ, Continuity, Frequency, NCVT, Temp, More, 1000V

User Manual - Page 3

For CL700.

PDF File Manual, 42 pages, Read Online | Download pdf file

CL700 photo
Loading ...
Loading ...
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy (50/60 Hz)
AC Voltage
(V AC)
6.000V 1mV ±(1.5% + 5 digits)
60.00V 10mV
±(1.2% + 5 digits)
600.0V 100mV
1000V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
600mV 0.1mV ±(1.0% + 8 digits)
6.000V 1mV
±(1.0% + 3 digits)60.00V 10mV
600.0V 100mV
1000V 1V ±(1.2% + 3 digits)
Input Impedance: 10MΩ
Frequency Range: 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
AC Current
(A AC)
60.00A 10mA ±(2.0% + 8 digits)
600.0A 100mA ±(2.0% + 5 digits)
Frequency Range: 50 to 60Hz
Function Range Resolution Accuracy
Resistance
600.0Ω 0.1Ω
±(1.5% + 5 digits)
6.000KΩ
60.00kΩ 10Ω
600.0kΩ 100Ω
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 10 digits)
Maximum Input: 600V AC RMS or 600V DC
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
Diode Test: Max. 1.5mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <50Ω, current <0.35mA
Sampling Frequency: 3 samples per second
Auto Power off: After ~30 minutes of inactivity.
Overload:
"OL" indicated on display, overload protection
1000V in Voltage setting, 600V RMS in all other settings
Polarity: "-" on display indicates negative polarity
Display: 3-5/6 digit, 6000 Count LCD