Tripp Lite OMNISMART1050MX 1050VA 540W 120V Line-Interactive UPS - 12 NEMA 5-15R Outlets, Double-Boost AVR, USB, Desktop/Wall-Mount

Owner's Manual - Page 5

For OMNISMART1050MX. Also, The document are for others Tripp Lite models: OMNISMART550MX, OMNISMART750MX

PDF File Manual, 24 pages, Read Online | Download pdf file

OMNISMART1050MX photo
Loading ...
Loading ...
Loading ...
5
Installation and Operation
LED Indicators
Description
ON/OFF
Power Status
(Green LED)
ON BATTERY
Mode
(Yellow LED)
OVERLOAD/
LOW BATTERY
(Red LED)
REPLACE
BATTERY
(Red LED) Alarm
AC Line Mode
Normal Operation
On Off Off Off Off
AC Line Mode
Overload Alarm
On Off Off Off Sounds every
0.5 seconds
AC Line Mode
Overload Fault*
Off Off On Off
Sounds
continuously
AC Line Mode
Replace Battery
On Off Off On Sounds every
1 minute
Battery Backup Mode
Full Charge**
Off Flashes every
10 seconds
Off Off Off
Battery Backup Mode
Low Battery
Off Flashes every
1 second
On Off Sounds every
1 second
Battery Backup Mode
Overload Alarm
Off Flashes every
0.5 seconds
Off Off Sounds every
0.5 seconds
Battery Backup
Mode Overload
Shutdown***
Off Off Off Off Off
Fault Mode
(Short Circuit/
Overcharge, etc.)
Off Off On Off Sounds
continuously
* UPS goes to Overload Fault Status (Line Mode) when load levels of 125% or greater occur for a duration of 10
minutes and 20 seconds.
** UPS remains silent in Battery Backup Mode until low-battery notification occurs.
*** UPS goes to Overload Shutdown (Battery Mode) with load levels of 110% or greater; Shutdown occurs
within 36 seconds.
Alarm Configuration Note: The alarm is factory configured to remain silent in battery mode until the low-
battery threshold occurs.
To configure the alarm to sound immediately in response to a power failure, press and hold the POWER
BUTTON until a single beep is heard, then release. The alarm will now be configured to sound immediately
when a power failure occurs.
IMPORTANT! The Power Button must be released immediately after the first beep in order to change the
alarm off/on status. Holding the switch down until the second beep will immediately power off the UPS.
Alarm OFF/ON status can be changed as the UPS runs in AC or Battery mode. Changing alarm status
activates a UPS preset that automatically remains in place until the next reset.