Quick Installation
STEP 3: Turn on the UPS.
After connecting your equipment to the UPS, press and hold the power button until a beep is heard,
then release to turn on your UPS.
If the on-line AC power icon does not illuminate when the UPS is turned ON, try the following:
1. Make sure the UPS is plugged into a live AC outlet.
2. Press the power button to turn on the UPS. A beep should sound when the UPS starts.
3. If the UPS still does not start, contact Tripp Lite Tech Support for assistance.
Basic Operation
UPS ON/OFF
Plug the UPS into a live, grounded outlet: The entire LCD screen will illuminate for 4 seconds,
then the display will report the output voltage of “0V”. BATTERY/SURGE PROTECTED outlets will be
OFF. The battery charger will engage as necessary.
Plug equipment into the UPS: You will overload the UPS if the total volt-amp (VA) ratings for
all the equipment connected to the BATTERY/SURGE PROTECTED outlets exceed the UPS output
capacity. To find your equipment’s VA ratings, look on their nameplates. If the equipment is listed
in amps (A), multiply the number of amps by 230 to determine VA. For example: 1A × 230 =
230VA.
Turn the UPS on: Press and hold the power button until the alarm sounds, then release. The
UPS alarm will beep for 2 seconds. The BATTERY/SURGE PROTECTED outlets will begin passing
AC line power. The UPS will automatically recharge internal batteries as needed. Once turned on,
your UPS is ready to protect connected equipment from blackouts, brownouts, overvoltages and
transient surges.
Turn the UPS off: Press the power button.
Note: UPS system will function properly upon initial startup. However, maximum runtime for the unit’s
battery will only be accessible after it has been charged for 24 hours.