4. Installation
2. Wall Installation
This type of installation is similar to roof mounting, ensuring that the pipe extends at least 55mm past the wall
surface refer gure 3. If the pipe length is shortened, reproduce the power cord exit slot on the inside of the
wall.
NOTE: By decreasing the length of the duct from which specied (refer to installation instructions) there will
be an increase in airow and noise levels as a result. This increase in airow can cause movement of air to be
heard through the system and inhibit the system to run silently.
Figure 2 Wall installation
Wall
Backdraft Shutter*
200mm Metal Pipe
From outside face of wall cover plate to end of
pipe (or wall if cover plate not used)
28
Locking screws
Power cord to
220-240V supply
Fill gap between pipe and
wall or t second wall cover
plate if required
Motor
Wall cover plate (optional)**
Weather shield
must be at top
IMPORTANT
It is a requirement to use the wall hanging bracket for all wall mount
installations. Please refer to the illustrations for mounting.
* With through wall installations ap shaft will be close to vertical.
** Optional parts are available from Schweigen, please contact 1300 881 693.
Wall