12 | nuwavenow.com
TURBO Mode
To quickly clear the air, choose the
TURBO Mode to run the OxyPure at
Fan Speed Level 6 (the highest) for
30 minutes, 1 hour, or 2 hours, after
which the unit will run at Fan Speed 1 if no other
buttons were pressed. If TURBO Mode is used
with other modes, it has priority. To use it:
Press TURBO and keep pressing the button
until the time you want is reached.
Once the selected time has nished the
OxyPure will run with last function selected.
TURBO + ULTIMATE CLEAN
Set the time you want for TURBO. Then, once
that time is reached, the unit will run under
ULTIMATE CLEAN until changed.
TURBO + AUTO
Press TURBO to the time desired and then
AUTO. The OxyPure will run in TURBO Mode
for selected time period, and then in AUTO Mode
until changed.
TURBO Mode + TIMER
When TURBO Mode is running, the user may set
the running time up to an additional 12 hours by
pressing TIMER.
The OxyPure will operate under TURBO Mode
rst for the selected time. It will then continue
to run for the time specied on the Timer.
After the Timer runs out, the unit will go on the
next mode or function.
Note
TURBO Mode and FAN SPEED do not work
together. Pressing FAN SPEED while TURBO
Mode is active will simply turn off TURBO Mode
and set the Fan Speed Level to 1.
INSTRUCTIONS
TURBO MODE • FILTER INDICATORS
Filter Indicators
To alert you to the need to clean your Bio-Guard
Filters, there are LED Filter Indicators beneath
the TIMER and TURBO buttons. These will light
up based on the length of operation as follows:
The Clean Filter 2 light will turn green after
about 3 months to alert you that the Bio-Guard
Filter(s) SHOULD be cleaned to maintain
optimal performance (NuWave Recommen-
dation). When the light turns red (after about
6 months), the Bio-Guard Filter(s) MUST be
cleaned.
Once cleaned, press and hold TIMER for 2
seconds until a beep is heard to reset the
Filter Indicator for Filter 2.
The Clean Filter 3 light will turn green in about
3 months to alert you that the Central Bio-
Guard Filter SHOULD be cleaned to maintain
optimal performance (NuWave Recommenda-
tion). When the light turns red (after about 6
months), the Central Bio-Guard Filter MUST
be cleaned.
Once cleaned, press and hold down TURBO
for 2 seconds until a beep is heard to reset the
Filter Indicator for Filter 3
Depending on your operating environment, you
may wish to clean the lters more frequently.
Remember...
ALWAYS remove the plastic wrapping from
new lters BEFORE using them in the
OxyPure.
Failing to do so may damage the motor and
other parts of the OxyPure and may void your
warranty