Installation Instruction - Page 12

For SDD2LEMTC1180WH. Also, The document are for others Sirius models: SDD2 L EMTC 580, SDD2 L EMTC 880, SDD2 L EMTC 1180, SDD2 L EMTC 580 WH, SDD2 L EMTC 880 WH, SDD2 L EMTC 1180 WH

Loading ...
Loading ...
Loading ...
12
POWER TRANSFORMER
7 METRE POWER CORD
Power transformer can be located anywhere beneath
the bench. It must be accessible for servicing.
ELECTRICAL CONNECTION
S-DD2-L FLUSH TOP
INSTALLATION GUIDE
DUCTING FROM MOTOR TO WALL VENT: (SEM 1 and SEM 8)
1. Run the length of ducting to the motor. (Additional lengths of ducting can be attached using an
additional internal connector pieces.)
NOTE: No connector required as it connects directly to the collar of the motor.
2. Secure with another universal ring clamp (Part ā€˜Gā€™).
NOTE: The location of the motor is to be no less than 2 metres away from the downdraft. Failure to
do so may result in additional noise level of the downdraft. Maximum distance is 7 metres, however
3 - 5 metres is optimum to minimise noise and maximise performance.
3. Using another length of semi-rigid duct run from the exit collar on the SEM 1 / SEM 8 to a predetermined
exit point and connect to weatherproof vent with a clamp.
See www.siriusbrand.com for multiple vent options or see our nearest retail partner.
WARNING
Place the power transformer at a distance of no
less than 65 cm from gas cooktops.
NOTE
We recommend installing the power transformer
at least 10 cm above floor level and at a suitable
distance from all heat sources (e.g. oven sides or
cook top).
Loading ...
Loading ...