Waldorf GP8450G-LS 800 Series 450mm Gas Griddle Leg Stand

Installation Operation Manual - Page 12

For GP8450G-LS.

PDF File Manual, 30 pages, Read Online | Download pdf file

GP8450G-LS photo
Loading ...
Loading ...
Loading ...
10
NOTE:
It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local gas, health and safety requirements.
This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in the room, appliance is
installed in.
Waldorf Gas Griddles are designed to provide years of satisfactory service and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia: - AS5601 - Gas Installations.
New Zealand: - NZS5261 - Gas Installation.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 - 1 & 2 Installation Flueing & Ventilation.
Ireland: - IS 820 - Non - Domestic Gas Installations.
Installations must be carried out by qualified persons only. Failure to install equipment to the
relevant codes and manufacturers specifications shown in this section will void the
warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Remove all packaging and transit protection from appliance including all protective plastic
coating from exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Ensure the 4 adjustable feet are securely fitted.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to that shown on rating plate located behind front control panel
and on inner face of right hand panel.
1. Installation must allow for sufficient flow of fresh air for combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3. Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. Minimum installation clearances shown overleaf are to be adhered to.
4. Position appliance in its approximate working position.
5. All air for burner combustion is supplied from beneath the unit. Legs must always be fitted and no
obstructions placed on beneath or around base of appliance, as obstructions will cause incorrect
operation and / or failure of appliance.
6. Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be
adjusted by an authorised service agent. They are not to be adjusted by the installation person.
NOTE: Do not obstruct or block appliance flue. Never directly connect a ventilation system to
appliance flue outlet.
Combustion Air Requirements:
GP514 GP516 GP518 GP513
Natural Gas 14m
3
/hr 21m
3
/hr 28m
3
/hr 10.5m
3
/hr
LPG / Butane 15m
3
/hr 22m
3
/hr 29m
3
/hr 11m
3
/hr
Town Gas 14m
3
/hr 21m
3
/hr 28m
3
/hr 10.5m
3
/hr
Loading ...
Loading ...
Loading ...