SYMPTOM CAUSE(S) CORRECTIVE ACTION
1. Timer will not keep time No trippers on dial Install trippers
Trippers are not installed properly Re-install trippers on dial
2. Timer dial is not turning Breaker OFF Turn ON Power
Timer motor dead due to lightning Replace timer
3. Pump operates off schedule Power failure earlier Reset timer
Breaker was OFF for some time Reset timer
4. Filter pump is ON at all timer Timer contacts welded Replace timer
5. Filter Pump will not start Defective thermostat (see Test procedure) Replace t.stat
when temp.is below 32 deg. Defective relay Replace relay
Defective wiring Check wiring
TROUBLESHOOTING
OPERATION
(CONT.)
3
1. Insert ON (green) and OFF (red)
trippers into dial at desired ON
and OFF times (Fig. 1).
2. Be sure trippers are firmly
pressed against dial surface and
at least one space is left between
ON and OFF trippers (Fig. 2).
3. Turn dial clockwise one or more
revolutions until correct time of
day is next to arrow in center of
dial (Fig. 3).
Manual Knob
ON Tripper (Green)
OFF Tripper (Red)
1. The knob in the upper left corner of timer is
for operating the Filter pump manually when
needed. By turning it COUNTERCLOCKWISE,
it will start or stop the filtering/heating cycle
ahead of the scheduled start/stop time.
Automatic operation will resume with the
next scheduled cycle.
2. Timer comes with two sets of trippers,
allowing the choice of two cycles per day.
If only one cycle is needed, the extra trippers
may be stored on the dial by placing SAME
color trippers next to each other.
3. To suspend automatic operation, remove red
and green trippers from Dial and Store them
in a convenient place.
4. Additional trippers can be obtained by con-
tracting an Intermatic distributor or Intermatic
Consumer Service at (815-675-7000 and ask-
ing for 156PB10398A tripper kit (2 ON and 2
OFF trippers.)