11
Before beginning turn off the equipment, and disconnect the plug.
Close and protect the unit.
- Unscrew, rotate and remove protective grill
- Remove the dust deposited on the front surface of the condenser
using a brush and a vacuum cleaner and restore previous conditions.
8.3 PERIOD OF INACTIVITY OF CABINET
During periods of inactivity, remove the products from the cabinet and
then follow these directions:
- Remove the plug out from the outlet and
carefully clean the unit as per periodic cleaning
- Cover the cabinet whit a cloth that allows air
circulation in the interior.
circulation in the interior.
9 TROUBLE SHOOTING AND REMEDIES
Often, the malfunction of a unit is due to simple causes which can easily
be eliminated without contacting a technician.
Therefore execute the following controls
9.1 If the cabinet does not operate,
make sure that:
- - The plug has been correctly inserted into the socket.
- The supply cord is not damaged.
9.2 If the required temperature is not achieved, make sure that;
- The command switch is turned on.
- The thermostat range is correctly regulated .