INSTALLATION CLEARANCES
When selecting the installation location for the Platinum
Smart-Heat Heaters, the following mounting clearances
should be followed.
Care should be taken to ensure that the heater is not
installed:
Where heat/ignition can cause damage to gas cylinders/
lines
Near other combustible materials
In open locations subject to rain
In indoor residential locations
In areas without sufficient clearances (refer below)
Note: When Installing with No protective cover, the following
installation clearances shall apply:
INSTALLATION REQUIREMENTS CONTINUED...
C
Minimum Mounting Height to Ground
B
A
Minimum height to combustible materials
Model A B C
300 Series
1100mm 1100mm
2000mm*
(Outdoor areas)
2500mm*
(Non-residential
indoor)
500 Series 1100mm 1100mm
2000mm*
(Outdoor areas)
2500mm*
(Non-residential
indoor)
*Bromic recommended minimum installation height. Local authority regulations and building codes
must be checked prior to installation.
Note: When installing with the Platinum Smart-Heat Heat
Shield (Part No. 2620165 or 2620166) the following
installation clearances Shall Apply:
C
Minimum Mounting Height to Ground
B
A
Minimum height to combustible materials
Model A B C
300 Series 350mm 1100mm
2000mm*
(Outdoor areas)
2500mm*
(Non-residential
indoor)
500 Series 350mm 1100mm
2000mm*
(Outdoor areas)
2500mm*
(Non-residential
indoor)
*Bromic recommended minimum installation height. Local authority regulations and building codes
must be checked prior to installation.
IMPORTANT
In the Case of appliances intended for non-residential indoor use:
This appliance must not be used in a room smaller than V cubic
metres.
Where V = Five (5) times the rated gas consumption (MJ/h).
NOTE: For example in the case of an appliance with a rated gas
consumption of 20 MJ/h, V = 5 x 20, 100 cubic metres.
IMPORTANT
This appliance must only be used in a well ventilated area.
The stated clearance to combustible materials represents
surface temperature of 65
o
C above room temperature.
Building material with a low heat tolerance (such as plastic,
vinyl siding, canvas, tri-ply etc.) may subject to degradation
at lower temperature. It is the installer's responsibility to
assure that adjacent materials are protected.