Beforeyoucall forservice... GEAppliances.com
Troubleshooting tips
Save time and money! Review the chart below first
and you may not need to call for service.
Possible Causes What ToDo
The air conditioner Make sure the air conditioner plug is pushed completely
is tmplugged, into the outlet.
The fuse is blown/cireult Check the house fltse/circuit breaker box and replace
breaker is tripped, the fi]se or reset tim breaker.
Power failure. If power failure occurs, turn the air conditoner OFF.
When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor
overload.
Airflow is restricted. * Make sure there are no curtains, blinds or fi]rniture
blocking tim front of the air conditioner.
The temp control may On models with touch pads: In COOL mode, press tim
not be set correcdy. DECREASE•pad.
On models with control knobs, turn the temperature
knob to a higher numbel:
The air Filter is dirty. Clean the filter at least every 30 days.
See tim Operating Instructions section.
The room may have been hot. When the air conditioner is first turned on you need to
allow time for the room to cool down.
Cold air is escaping. Check for open fi]rnace floor registers and cold air
Feturils.
Set tim air conditioner's vent to tim closed position.
Cooling coils have iced up. See "air conditioner froozinfl up" below.
Ice blocks the air flow On models with control knobs, set the mode control at
and stops the air conditioner HIGH FANor HIGH COOLwith the temp at t or 2.
from cooling the room. On models with touch pads, set the controls at
HIGH (F3)FAN or HIGH (F3)COOLand set the thermostat
to a higher temperature.
The batteries are inserted Check the position of the batteries. _i]ley should be
incorrectly, inserted in the opposite (+) and (-) direction.
The batteries may be dead. Replace tim batteries.
Excessively hot and This is normal.
humid weather.
The air conditioner is not For proper water disposal, make sure the air conditoner
tilted to the outside, slants slightly" from the case fi'ont to tim rein:
Wato_llo_tsin Moisture is removed from
: indoor air and drains into
rear of a cabinet where a fan
blows it against the outdoor
condenser coil.
This is normal for a short period in areas with little
humidity; normal for a longer period in very humid
areas.