If range does not operate, check the following:
Household fuse is intact and tight, or circuit breaker has not
tripped.
Gas valves are turned to the "open" position.
If the gas supply line shutoff valve is open, press the OFF
button on the oven control panel and contact a qualified
technician.
Electrical supply is connected.
See "Troubleshooting" in the Use and Care Guide.
When the range has been on for 5 minutes, check for heat. If
range is cold, turn off the range and contact a qualified
technician.
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas; or from LP gas to
Natural gas must be done by a qualified installer.
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position.
2. Unplug range or disconnect power.
.... B
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
3. Remove warming drawer. See the "Remove Warming
Drawer" section for instructions. Locate gas pressure
regulator at rear of warming drawer compartment.
4. Remove access cover from the gas pressure regulator.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
6. Remove sprint retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "NAT" or "LP" position.
7. Turn over the spring retainer so the "LP" is showing on the
bottom.
8. Snap the spring retainer back into the cap.