Loading ...
Loading ...
Loading ...
Installation instructions en
15
5.
Restore the control panel cabling and the cabling
for the lighting.
The plug can only be inserted into one position.
6.
Ensure that the connector has engaged correctly.
7.
Fit the grease filters.
To avoid causing damage, do not bend the grease
filters.
8.
Attach and close the filter cover.
Establishing the exhaust air connection
1.
Secure the exhaust pipe to the air pipe connector.
2.
Establish the connection to the exhaust air opening.
3.
Seal the joints.
Establishing the connection for the circulated
air
The standard recirculation kit is available as an access-
ory.
1.
Secure the exhaust pipe to the air pipe connector.
2.
Connect the pipe to the opening on the fitted unit.
3.
Screw the air guide grille to the fitted unit.
4.
Seal the joints.
Connecting to the power supply
1.
Insert the mains plug into the protective contact
socket.
2.
If a fixed connection is required, follow the instruc-
tions in the section
→"Instructions for the electrical connection",
Page12.
Removing the appliance
WARNING‒Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
1.
Disconnect the appliance from the power supply.
2.
Loosen the exhaust pipe.
3.
Open the filter cover if required.
4.
Remove the grease filters.
To avoid causing damage, do not bend the grease
filters.
5.
Remove the frame.
6.
Undo the control panel cabling and cabling for the
lighting.
7.
Loosen the screw connection with the fitted unit.
8.
Slowly take the appliance down.
Loading ...