Ancona AN-18056SS 30" 160 CFM Convertible Under Cabinet Range Hood in Stainless steel

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Dimension Guide
AN-18056SS photo

User Manual and Installation Instructions

This is the main product document for model AN-18056SS.

The file format is pdf, 18 pages, you can download this manual here .

background
Under Cabinet Range Hood
User Manual
and
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
Carefully read the important information
regarding installation, safety and maintenance.
Keep these instructions for future reference.
MAAN18056SS-01
2023-02-08
background
— 2 —
INSTALLERS - Start Here
Safety Instructions are on pages 4 and 5 and
Installation Instructions are on pages 8 to 14.
Please perform these steps:
1. Read the safety instructions.
2. Read all instructions in the Installation section of
this manual BEFORE installing the range hood.
3. Remove all packing materials.
4. When nished, make sure to leave these instructions with the consumer.
5. Installation is to be done by a qualied technician only. However, the
ultimate responsibility for proper installation falls to the owner.
6.
Product failure due to improper installation is not covered under the Warranty.
CONSUMERS - Start Here
Safety Instructions are on pages 4 and 5 and Operating Instructions are
on pages 15 to 17.
Please perform these steps:
1. Read the safety instructions.
2. Read all instructions in the manual BEFORE operating the range hood.
3. Remove all packing materials.
4. Installation is to be done by a qualied technician only. However, the
ultimate responsibility for proper installation falls to the owner.
5.
Product failure due to improper installation is not covered under the Warranty.
Before You Begin
Hardware Note: For safety reasons, range hood mounting screws and
anchors will not be included due to the variation of cabinetry constructions
and wall material. Please consult your installation specialist regarding the
optimal type of mounting screws and wall anchors to suit your home’s
construction.
background
— 3 —
Before You Begin ............................................................................................................................... 2
Table of Contents .............................................................................................................................. 3
Important Safety Information ............................................................................................................ 4
Included Parts ................................................................................................................................... 6
Range Hood Dimensions .................................................................................................................. 7
Specications .................................................................................................................................... 7
Installation ......................................................................................................................................... 8
Step 1 - Read the Safety Instructions ............................................................................................ 8
Step 2 - Unpack Range Hood and Prepare Tools .......................................................................... 8
Step 3 - Plan Desired Location ...................................................................................................... 8
Step 4 - Test Unit Functions .......................................................................................................... 8
Step 5 - Venting Installation Guidelines ......................................................................................... 9
Step 6 - Preparations ................................................................................................................... 11
Step 7 - Remove Accessories ...................................................................................................... 11
Step 8 (External Ventilation Only) - Attaching Vent/Damper and Panel Piece ............................. 12
Step 9 - Electrical Connection ..................................................................................................... 13
Step 10A - Wall installation .......................................................................................................... 14
Step 10B - Under the cabinet installation .................................................................................... 14
Step 11 (External Ventilation Only) - Venting ............................................................................... 14
Operation ........................................................................................................................................ 15
Power ........................................................................................................................................... 15
Light ............................................................................................................................................. 15
Troubleshooting............................................................................................................................... 15
Maintenance.................................................................................................................................... 16
Hood Cleaning ............................................................................................................................. 16
Replacing the Light ...................................................................................................................... 16
Use and Care Information ............................................................................................................... 17
Table of Contents
background
— 4 —
Important Safety Information
• Theinstallationinthismanualisintended
for qualied installers, service technicians or
persons with a similar qualied background.
Installation must be done by qualied
professionals and in accordance with all
applicable codes and standards, including
re-rated construction.
•
The range hood may have very sharp
edges; please wear protective gloves if it is
necessary to remove any parts for installing,
cleaning or servicing.
•
Activating any switch to ON position before
completing installation may cause damage or
electric shock.
• Duetothesizeofthisrangehood,atwo-
person installation is recommended.
To reduce the risk of fire, electric shock, or
injury to persons:
• Forgeneralventilatinguseonly.DO NOT use
toexhausthazardousorexplosivematerials
and vapours.
• WARNING: To Reduce The Risk Of Fire Or
Electric Shock, Do Not Use This Fan With Any
Solid-State Speed Control Device.
• Thecombustionairowneededforsafe
operation of fuel-burning equipment may be
affected by this unit’s operation. Follow the
heating equipment manufacturer’s guideline
and safety standards such as those published
by the National Fire Protection Association
(NFPA), and the American Society of Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and other local code authorities.
• Beforeservicingorcleaningtheunit,switch
power off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
• Cleangrease-ladensurfacesfrequently.To
optimizeperformanceandtodisperseair
properly, make sure to vent air outside. DO
NOT vent exhaust into spaces between walls,
crawl spaces, ceilings, attics or garages.
•
Ducted fans MUST always be vented to
the outdoors.
• ThisunitMUSTbegroundedandusedwith
metal ductwork only.
• Sufcientairisneededforpropercombustion
and exhausting of gases through the duct to
prevent back drafting.
• Whencuttingordrillingintowallorceiling,be
careful not to damage electrical wiring or other
hidden utilities.
• Allelectricalwiringmustbeproperlyinstalled,
insulated and grounded.
•
Old ductwork should be cleaned or replaced
if necessary to avoid the possibility of a
grease re.
•
Check all joints on ductwork to ensure
proper connection; all joints should be
properly taped using a certied aluminum
or foil tape.
• Usethisunitonlyinthemannerintended
by the manufacturer. If you have questions,
contact the vendor.
READ AND SAVE THESE
INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Read and follow all instructions before using the range hood to prevent the risk of re, electric shock,
personal injury, or damage when using the range hood or appliances with the range hood. This guide
does not cover all possible conditions that may occur. Always contact your service technician or
manufacturer about problems that you do not understand.
background
— 5 —
Important Safety Information
WARNING: TO REDUCE RISK OF A RANGE
TOP GREASE FIRE:
a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.
b) Always turn range hood ON when cooking at
highheatorwhenambéingfood(i.e.Crepes
Suzette,CherriesJubilee,etc.).
c)
Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or lter.
Before servicing or cleaning unit, unplug and
disconnect the hood from the power supply.
d)Useproperpansize.Alwaysusecookware
appropriateforthesizeofthesurfaceelement.
WARNING: TO REDUCE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING *
a) S
MOTHER FLAMES with a close-tting
lid, cookie sheet, or metal tray, then turn
off the burner. BE CAREFUL TO PREVENT
BURNS.Iftheamesdonotgoout
immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may
be burned.
c) DO NOT USE WATER, including wet dishcloths
or towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class A, B, C
extinguisher, and you already know how to
operate it.
2) The re is small and contained in the area
where it is started.
3) The re department is being called.
4)
You can ght the re with your back to an exit.
* Based on “Kitchen Fire Safety Tips”
published by NFPA
To reduce the risk of injury to persons in the
event of a gas leaks:
• Extinguishanyopename.
•
DO NOT turn on the lights or any type of appliance.
• Openalldoorsandwindowstodispersethe
gas. If you still smell gas, call the gas company
and re department.
Your safety and the safety of others is very
important. We have provided many important
safety messages in this manual and on your
appliance. Always read and obey all safety
messages. All safety messages outline any
potentialhazards,howtoreducethechanceof
injury, and possible risks if the instructions are not
followed.
READ AND SAVE THESE
INSTRUCTIONS
background
— 6 —
Included Parts
Hardware Note: For safety reasons, range hood mounting screws and anchors will
not be included due to the variation of cabinetry constructions and wall material.
Please consult your installation specialist regarding the optimal type of mounting
screws and wall anchors to suit your home’s construction.
Range Hood
Filter
4 + 1 ScrewsRectangular Vent/Damper Panel piece
background
— 7 —
Range Hood Dimensions
Specifications
Body Design Stainless Steel
Power Rating 120V/60Hz(cETLusCertied)
Total Input Power 52 W (50 W + 2 W)
Motor Input Power 50 W
Amperage 0.43 A
Speed Control Levels 2 Speeds
Interference Protection Radio Frequency Interference Protected
Motors Single Motor
Fan Type Centrifugal Squirrel Cage
Controls Rocker switch
Filtration Aluminium lter with charcoal cotton sheet
Lighting 1 × 2 W LED
Light Intensity Levels 1
VentingSize 3 1/4 × 10 inch (8.3 cm × 25.4 cm) rectangle, top or rear
or purchase separately top 6 inches (15.3 cm) round
29.9” (76 cm)
9.9” (25.2 cm)
3.1” (8 cm)
11.8” (30.1 cm)
4.7” (12 cm)
17.5” (44.5 cm)
9” (22.9 cm)
27.8” (70.6 cm)
9.9” (25.2 cm)
3.1” (8 cm)
27.8” (70.6 cm)
background
— 8 —
STEP 1
Read the Safety Instructions
• It is very important to read the safety instructions on pages 4 and 5.
IMPORTANT: It is the installer’s responsibility to comply with installation clearances.
STEP 2
Unpack Range Hood and Prepare Tools
• Carefully unpack the range hood and parts. Make sure all parts are included as shown on page 6.
• DO NOT remove the protective lm covering the appliance until the installation is fully completed.
• Consult a qualied and trained installer or check local codes for makeup air requirement, if any.
STEP 3
Plan Desired Location
• Plan a desirable location that ts all requirements in the Safety and Installation sections of this manual. Plan where
and how the ductwork will be installed.
• A straight or short duct run will allow the unit to perform most efciently. Long duct runs, elbows and transitions
will reduce the performance of the unit. Each elbow is equivalent to 5 to 10 feet (1.5 m to 3 m) of straight run.
• If ductwork is already installed: ensure ductwork is free from debris.
STEP 4
Test Unit Functions
• Plug the unit in and test all of the functions before installing.
• Placetherangehoodonaat,stablesurface.Connecttherangehoodtoadesignatedstandardoutlet(120-Volt,60Hz,
AC only) and turn on the range hood. Verify all operations of the range hood by referring to
Range Hood Operations.
• Turn power On in control panel.
• Check all lights and fan operations.
WARNINGS:
• PleasemakesuretoreadALLsafetyinstructionsonpages4and5.
• Usetwoormorepeopletomoveandinstallrangehood.
• Failuretofollowtheseinstructionscanresultinseriousinjury.
Installation
background
— 9 —
Installation
STEP 5
Venting Installation Guidelines
• The following steps are for exterior ventilation.
Height and Clearance
IMPORTANT:
•
Vent system must terminate to the outside (roof or side wall).
• DONOT
terminate the vent system in an attic or other
enclosed area.
• DONOTuse4in(10.2cm)laundry-typewallcaps.
• Usemetal/aluminumventonly.Arigidmetal/aluminum
vent is recommended.
• DONOTuseaplasticvent.
• Alwayskeeptheductcleantoensureproperairflow.
• Calculatethefollowingfiguresbeforeinstallation:
1. Distance from the floor to the ceiling
2. Distance between the floor and the countertop/stove
3.
A distance of 24 in to 30 in (61 cm to 76.2 cm) is
recommended between stove top and the bottom of
range hood. 30 in (76.2 cm) minimum is required for
gas stove tops.
4. Height of hood and duct cover.
For the most efficient and quiet operation:
• Itisrecommendedthattherangehoodbevented
vertically through the roof through 6 in. (15.3 cm) round,
or through the roof or wall 3-1/4 × 10 in. (8.3 cm × 25.4
cm) rectangular duct or bigger metal/aluminum vent
work.
• Thesizeoftheventshouldbeuniform.
• Usenomorethanthree90°elbows.
•
Make sure there is a minimum of 24 in (61 cm) of
straight vent between the elbows if more than one
elbow is used.
• DONOTinstalltwoelbowstogether.
•
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
• Theventsystemmusthaveadamper.Ifrooforwall
cap has a damper, you may remove damper flaps from
damper to increase air flow.
• Onlyoneflangeisneededintheairductsystem,either
on top of the motor or outside.
•
Use silver tape or duct tape to seal all joints in the
vent system.
•
Use caulking to seal exterior wall or roof opening
around the cap.
24 in. (610 mm) Min / 30 in. (762 mm) Max
background
— 10 —
IMPORTANT:
•
A minimum of 6 in. (15.3 cm) round or 3-1/4 × 10 in. (8.3
cm × 25.4 cm) rectangular duct must be used to maintain
maximum airflow efficiency.
• Alwaysuserigidtypemetal/aluminumductsifavailableto
maximizeairflowwhenconnectingtoprovidedduct.
• PleaseuseDuctRunCalculationbelowtocompute
total available duct run when using elbows, transitions
and caps.
• ALWAYS,whenpossible,reducethenumberor
transitions and turns. If long duct run is required,
increaseductsizefrom6in.(15.3cm)to7in.(17.7
cm) or 8 in. (20.3 cm). If a reducer is used, install a
long reducer instead of a pancake reducer. Reducing
ductsizewillrestrictairflowanddecreaseairflow,thus
reduceductsizeasfarawayfromopeningaspossible.
• Ifturnsortransitionsarerequired,installasfaraway
from opening and as far apart, between two (2), as
possible.
• Minimummountheightbetweenstovetoptohood
bottom should be no less than 24-inch (61 cm) for
electric cook tops and minimum of 30-inch (76.2 cm)
for gas stove tops and no higher than 30-inch (76.2 cm)
for electric cook tops.
• Itisimportanttoinstallthehoodatthepropermounting
height. Hoods mounted too low could result in heat
damageandfirehazard;whilehoodsmountedtoohigh
may be hard to reach and will lose its performance and
efficiency.
• Ifavailable,alsorefertostovetopmanufacturer’s
height clearance requirements and recommended
hood mounting height above range.
Installation
• This range hood is factory set for venting through the roof or wall.
• Ventworkcanterminateeitherthroughtherooforwall.Toventthroughawall,a90°elbowisneeded.
IMPORTANT:
• NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or
garages. All exhaust must be ducted to the outside.
• Use metal/aluminum duct work only.
• Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.
• Use caulking to seal exterior wall or roof opening around the cap.
Duct Run
Calculation
example:
One roof cap, two
90º elbows, and
one 45º elbow use.
0ft + 9ft + 9ft + 5ft
= 23ft used.
Deduct 23ft from
30ft, 7ft maximum
available for
straight duct run.
TOP VENTING
ROOF EXHAUST
TOP VENTING
WALL EXHAUST
REAR VENTING
background
— 11 —
STEP 7
Remove Accessories
• Unscrew and remove corner bead located underneath the hood
(see Figure 1).
• Unscrew the rectangular damper located underneath the hood,
by removing top screws (see Figure 2).
• Use a tool to punch the wiring hole, from the two options for
holes. Please choose hole A or hole B according to wiring
requirement (see Figure 3).
Installation
STEP 6
Preparations
NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.
• Determine and mark the centre line on the ceiling or wall where the range hood will be installed.
• Make sure there is proper clearance within the ceiling or wall for exhaust vent.
• Duetotheweightandsizeofthisunit,pleasemakesurethatthesupportsystemorframeworkbeingusedisstableand
secure in the ceiling or wall.
• Put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt.
• Removeanyhazardousobjectsaroundtheareawheninstalling.
CAUTION
If moving the cooking range is necessary to install the hood, turn OFF the power on an electric range at the main
electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.
Figure 1
Figure 2 Figure 3
A
B
background
— 12 —
Installation
Figure 4
Figure 5A Figure 5B
STEP 8 (External Ventilation Only)
Attaching Vent/Damper and Panel Piece
• Depending on the exterior venting option chosen (see page 10), pop
out the steel panel on either the top or rear of the range hood (see
Figure 4).
• Using the supplied screws, attach the rectangular vent/damper on
either the top or rear of the range hood (see Figure 5A or 5B).
• If using top round 6 in. ducting, please purchase Ancona 6” damper (PRH-1275) separately.
• Take out the panel piece from the hardware bag.
• Insert the “panel piece” into the hood as shown on Figure 6.
• For external ventilation, please follow step 8.
• For internal re-circulation, please follow step 9.
Figure 6
background
— 13 —
STEP 9
Electrical Connection
• Depending if using the wiring hole A or hole B, connect cable to range
hood wiring (see Figure 7).
• Connect BLACK to BLACK, WHITE to WHITE and GREEN to GREEN
(see Figure 8).
• DON’T FORGET TO CONNECT THE GROUND! (green wire)
SAFETY WARNING: Risk of electrical shock. This range hood
must be properly grounded. Make sure this is done by a qualified
electrician in accordance with all applicable national and local
electrical codes. Before connecting wires, switch power off at service
panel and lock service panel to prevent power from being switched on
accidentally.
Figure 7
Figure 8
IMPORTANT:
• Observeallgoverningcodesandordinances.
• It is the customer’s responsibility to contact a qualified electrical installer.
• Ifcodespermitandaseparategroundwireisused,itisrecommendedthata
qualified electrician determine that the ground path is adequate. A 120-Volt, 60
Hz,AC-only,fusedelectricalsupplyisrequiredonaseparate15-ampcircuit,
fused on both sides of the line.
• DONOTgroundtoagaspipe.
• Checkwithaqualifiedelectricianifyouarenotsurethattherangehoodisproperlygrounded.
• DONOThaveafuseintheneutralorgroundcircuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
GROUNDING INSTRUCTIONS:
• Thisappliancemustbegrounded.Intheeventofanelectricalshort-circuit,groundingreducestheriskofelectric
shock by providing an escape wire for the electric current.
WARNING: Improper grounding can result in a risk of electric shock.
• Consultaqualifiedelectricianifthegroundinginstructionsarenotcompletelyunderstood,orifdoubtexistsasto
whether the appliance is properly grounded. DO NOT use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance.
• Therangehoodmustbeconnectedwithcopperwire/plugonly.Therangehoodshouldbeconnecteddirectlyto
the fused disconnect (or circuit breaker) box through flexible armored or non-metallic sheathed copper cable. UL/
CSA listed strain relief must be provided at each end of the power supply cable. Use only with range hood cord-
connection kits that have been investigated and found acceptable for use with this model.
E
N
L
Installation
E
N
L
background
— 14 —
Figure 9
Figure 10
STEP 10A
Wall installation
• Mark or drill a small hole on the mounting position
according to the dimensions on Figure 9.
• Insert suitable screws into the holes.
• Hang the range hood onto the screws.
• For wall installation, please follow step 10A.
• For cabinet installation, please follow step 10B.
STEP 10B
Under the cabinet installation
• Mark or drill a small hole on the mounting position according to the space and dimensions cited on Figure 10.
• Install the hood under the cabinet using suitable screws to x in position.
Installation
27.8” (70.6 cm)
0.81”
(2 cm)
27.8” (70.6 cm)
8.98”
(22.8 cm)
STEP 11 (External Ventilation Only)
Venting
• Depending on exterior ventilation chosen (see page 10), either exit the ducting through the ceiling or wall.
• Alwaysuserigidtypemetal/aluminumducttube(followthebuildingcodesinyourarea)tomaximizeairow.Makesure
thatthebackdraftapscanopen,toallowmaximumairow.Connecttheducttubetothevent/damperandsecurely
seal with certied aluminum or foil tape so that it is airtight. Please check the building codes in your city to learn which
tape product is recommended.
background
— 15 —
Operation
Speed button Light button
Power
u
Press on | button for low speed.
v
Press on || button for high speed.
w
Press middle O to turn off.
Light
u
Press button to turn light on and off.
Troubleshooting
Problem Possible Cause
If the range hood or LED light
does not operate after installation:
Check if the range hood has been plugged in, make sure that all power
has been turned back ON, fused not blown and all electrical wiring are
properly connected.
The range hood vibrates when the
blower is on:
The range hood might not have been secured properly on to the ceiling or
wall.
The blower or fan seems weak: Checkthattheductsizedusedisatleast6in.(15.3cm)or31/4×10in.
(8.3 × 25.4 cm). Range hood WILL NOT function efciently with insufcient
ductsize.Forexample:7in.(17.7cm)ductover6in.(15.3cm)holeand
loosely secured.
Checkifductiscloggedorifdamperunit(half-circularange)isnot
installed correctly or opening properly. A tight mesh on a side wall cap unit
mightalsocauserestrictiontotheairow.
The lights work but the fan is not
spinning at all, is stuck or is rattling:
The fan might be jammed or scraping the bottom due to shipping damage.
Please contact us immediately.
The hood is not venting out
properly:
Make sure the distance between the stove top and the bottom of the hood
is within 24 in. and 30 in. (61 and 76.2 cm) in distance.
Reduce the number of elbows and length of duct work. Check if all joints
are properly connected, sealed, and taped.
background
— 16 —
Proper maintenance of the Range Hood will ensure proper performance of the unit.
Use a warm detergent solution. Grease lters are dishwasher safe.
Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its appearance.
Cleaning tips:
• Hot water with soap or detergent is all that is usually required.
• Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
• For discolorations or deposits that persist, use a non-scratching household cleanser or stainless steel polishing powder
with a little water and a soft cloth.
• For stubborn cases, use a plastic scouring pad or soft bristle brush with cleanser and water. Rub lightly in direction of
polishing lines or “grain” of the stainless nish. Avoid using too much pressure, which may mar the surface.
• DO NOT allow deposits to remain on surface for long periods of time.
• DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.
• DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel
for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after
exposure and wipe dry with a clean cloth.
Painted surfaces should be cleaned with warm water and mild detergent only.
Maintenance
Hood Cleaning
u
Make sure the range hood is unplugged or turn OFF
breaker.
v
Open the wiring compartment with a Phillips
screwdriver, and unplug the light (Figure 11). Gently
use screwdriver to push down until light pops out
from its location. Pull out the LED light.
CAUTION: LIGHT MAY BE HOT, PLEASE TAKE
OUT THE LIGHT WHEN THE LIGHT IS
COMPLETELY COOL!
w
Replace with appropriate LED light. Please contact
Ancona customer service for replacement. Plug in
new light and push back into light panel.
x
Turn ON breaker and range hood to test for
operation.
Replacing the Light
IMPORTANT:
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION
ON THE APPLIANCE.
Figure 11
background
— 17 —
Use and Care Information
Operations
• Read and understand all instructions and warnings in this manual before operating the appliance. Save these
instructions for future reference.
• Always leave safety grills and lters in place. Without these components, operating fans could catch on to hair, ngers
and loose clothing.
• NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into fans.
• NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch re. The risk of self
combustion is higher when the oil has been used several times.
• NEVERcookon“open”amesundertherangehood.Checkdeep-fryersduringuse;superheatedoilmaybe
ammable.
Cleaning
• Thesaturationofgreasyresidueinthefanandltersmaycauseincreasedinammability.Keepunitcleanandfreeof
grease and residue build-up at all times to prevent possible res.
• Filters must be cleaned periodically and free from accumulation of cooking residue (see Cleaning Instructions below).
Old and worn lters must be replaced immediately.
• DO NOT operate fans when lters are removed. Never disassemble parts to clean without proper instructions.
Disassembly is recommended to be performed by qualied personnel only. Read and understand all instructions and
warnings in this manual before proceeding.
SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating!
For optimal operation, clean range hood and all baffle/spacer/filter/grease tray/oil container regularly. Regular care
will help preserve the appearance of the range hood.
Cleaning Exterior Surfaces
• Clean periodically with hot soapy water and clean cotton cloth. DO NOT use corrosive or abrasive detergent (e.g. Comet
Power Scrub®, EZ-Off® oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel
surface. For heavier soil use liquid degrease such as “Formula 409®” or “Fantastic®” brand cleaner.
• If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting
cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. CAUTION: DO NOT
leave on too long as this may cause damage to hood finish. Use soft towel to wipe off the cleaning solution, gently
rub off any stubborn spots. Use dry soft towel to dry the hood.
• After cleaning, you may use non-abrasive stainless steel polish such as 3M® or ZEP®, to polish and buff out the
stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
• DO NOT allow deposits to accumulate or remain on the hood.
• DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.
• DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel
for extended periods. Many of these compounds contain chemicals, which may be harmful.
• Rinse with water after exposure to these compounds and wipe dry with a clean cloth.
background
— 18 —
© 2023 Copyright of Ancona Home. All rights reserved. This material may not be reproduced, displayed, modied or distributed.
MAAN18056SS-01
Please register your product warranty by visiting the Ancona Home website.
Canada & USA
Phone: 1-800-350-4562
Fax: 800-350-8563
Website: www.anconahome.com
Ancona is in association with Mr Appliance for all after sales service calls.
Please contact their service provider or visit their website:
Phone: 1-888-998-2011
Website: www.mrappliance.com

Specifications

Ancona AN-18056SS Questions and Answers

Questions and Answers

Related Products