Sharp FP-G50E-W 40m² Air Purifier

User Manual - Page 13

For FP-G50E-W.

PDF File Manual, 40 pages, Read Online | Download pdf file

FP-G50E-W photo
Loading ...
Loading ...
Loading ...
ENGLISH
E-11
Power supply 220-240V 50-60Hz
Fan
Speed
Operation
Fan Speed Adjustment MAX MED SLEEP
*1
Rated Power 47W 16W 4.0~5.5W
Fan Speed 306m
3
/hour 186m
3
/hour 48~90m
3
/hour
Recommended Room Size ~40m
2
*2
High density Plasmacluster ion recommended room size
~23m
2
*3
Cord Length 2.0m
Dimensions 383mm(W)x209mm(D)x540mm(H)
Weight 5.1kg
*1 The fan speed is automatically switched depending on the amount of impurities in the air.
*2 Size of a room which is appropriate for operating the unit at maximum fan speed.
It indicates the space where a certain amount of dust particles can be removed in 30 minutes
(JEM1467).
*3 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the
center of the room (at a height of approximately 1.2 meters from the oor) when the product is
placed next to a wall and run at the MED operation position.
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the
wall outlet, this product consumes about 1.0W of standby power.
For energy saving, unplug the power cord when the unit is not in use.
SYMPTOM REMEDY (not a malfunction)
AUTO RESTART
After a power failure, automatically
resume the operation when the
power recovers.
Auto Restart can be set.
Even when the plug is unplugged or the breaker is thrown
during the operation, the operation resumes at the previous
operation mode and settings if the power recovers.
SPECIFICATIONS
ON OFF
(with the unit OFF) (with the unit OFF)
If the , , lamp Lights up
for 10 seconds, the setting is completed.
(simultaneously for more than 3 sec.) (simultaneously for more than 3 sec.)
OM_FP-G50E_50L_EN.indd Sec1:11OM_FP-G50E_50L_EN.indd Sec1:11 9/9/2559 BE 14:379/9/2559 BE 14:37
Loading ...
Loading ...
Loading ...