20
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at the ‘High’
setting. Operating pressure is ex-factory set through appliance regulator and is not to be adjusted,
apart from when carrying out gas conversion. (Refer to ‘Gas Conversion’ section for details).
Burner Injector
Ø 2.10mm Ø 1.25mm
Open Burner
Low Fire Setting
¾ turn open c.c.w. ¼ turn open c.c.w.
Burner Aeration Setting
16mm open. 16mm open.
Pilot Injector
0.30mm 0.20mm.
Griddle
Burner Injector
Ø 2.00mm Ø 1.25mm
Low Fire Setting
5
/
8
turn open c.c.w.
3
/
8
turn open c.c.w.
Burner Aeration Setting
Fully open. Fully open.
Pilot Injector
0.35 0.23
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa 2.6 kPa
Gas Regulator Cap Screw