CARE AND MAINTENANCE
CLEANING:
Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.
Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.
Clean intake and exhaust vents by wiping with a dry, soft cloth.
Unlock access panel: to unlock, insert the
key provided and rotate counter-clockwise
¼ turn.
Touch and hold the illuminated
indicator for three seconds until
a beep is heard and the indicator
is flashing green.
Open front access panel by pressing latches
on both sides of unit. Allow panel to open
fully. Remove filter(s) to be replaced.
Release finger from indicator.
Remove any packaging wrap from the
new filters(s) and re-install the filters.
Touch and hold the indicator for three
seconds until a beep is heard and the
indicator light turns off.
1
FILTER REPLACEMENT INDICATORS:
The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon with Pre-Filter. The replacement period will vary depending on the hours of
use, air quality, and rate of air flow. However, under normal usage, most HEPA Filters need to be replaced every 2 years, and Carbon with Pre-Filter every 6 months.
When a filter needs to be replaced the following color will be shown on any one of the HEPA, CARBON, or ACCESSORY filter replacement indicators:
Red flashing = 90% filter wear (recommendation to order new filters)
Red steady = 100% filter wear (replace with new filters)
Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax
®
PRO brand replacement filters as units will not function using
any other replacements.
FILTER REPLACEMENT PROCEDURE:
FILTER REPLACEMENT:
When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators.
To reset any of the filter replacement indicators use the following procedure:
TROUBLESHOOTING
PROBLEM: POSSIBLE SOLUTION:
The air quality control system fails to start.
Check to assure unit is connected to power supply.
Make sure filters are genuine AeraMax
®
PRO filters, as unit will not function with other
brands. IMPORTANT: Make sure filter detection area on genuine AeraMax
®
PRO
replacement filter aligns with window in filter frame.
Review “Re-Installing Filters” section for further detail.
Make sure front access panel is closed completely.
Make sure power switch is on.
The unit makes a faint ticking sound. This indicates that the “PlasmaTRUE™” bipolar ionizer is working.
The HEPA and/or Carbon Filter replacement indicator light
remain lit after replacing the filter(s).
Repeat filter light reset instruction.
Note: If you do not complete step three within 10 seconds of completing step 1 then the indicator light will not be reset.