Waldorf CHLB8120G-LS Bold 1200mm Gas Chargrill Low Back Version Leg Stand

Installation Operation Manual - Page 10

For CHLB8120G-LS.

PDF File Manual, 29 pages, Read Online | Download pdf file

CHLB8120G-LS photo
Loading ...
Loading ...
Loading ...
8
NOTE:
It is most important that this appliance is installed correctly and that operation is
correct before use. Installation shall comply with local gas, health and safety
requirements.
This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance
is installed in.
Waldorf Chargrills are designed to provide years of satisfactory service, and correct installation is essential
to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National Installation Codes and in addition, in
accordance with relevant National / Local Codes covering gas and fire safety.
Australia / New Zealand:: - AS5601.1 - Gas Installations.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 - 1 & 2 Installation Flueing & Ventilation.
Ireland: - IS 820 - Non-Domestic Gas Installations.
Installations must be carried out by qualified persons only. Failure to install equipment to the
relevant codes and manufacturers specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be
adjusted by an authorised service agent. They are not to be adjusted by the installation person.
Remove all packaging.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Remove protective plastic coating from side panels.
Check that the following parts have been supplied with chargrill:
1 x Gas Regulator.
1 x Gas Type Conversion Kit.
Report any deficiencies to distributor who supplied chargrill.
Check available gas supply is correct to that shown on rating plate attached to underside of R/H
side, front hob lower trim.
1. This appliance must be installed in a suitably ventilated room to prevent dangerous build up of
combustion products.
2. Installation must allow for a sufficient flow of fresh air for combustion air supply. Combustion air
requirements are:-
3. Never directly connect a ventilation system to the appliance flue outlet.
4. Position chargrill in its approximate working position.
NOTE: Do not obstruct or block the appliance flue. Never directly connect a ventilation
system to the appliance flue outlet.
Natural Gas (G20)
9m
3
/hr 18m
3
/hr 27m
3
/hr 36m
3
/hr 14m
3
/hr
LPG Gas (G30 / G31)
9m
3
/hr 18m
3
/hr 26m
3
/hr 35m
3
/hr 13m
3
/hr
Loading ...
Loading ...
Loading ...