Option4: No waste disposer, no drain air gap
A
2. Route electrical wires through strain relief and secure to
electrical plate.
C
6=
A. Drain hose connector
B. Cut drain connector
C. Waste
NOTE: Attach the drain hose connector to the water waste
line using the supplied hose clamp.
Turn on water and check for leaks.
1=
Electrical Shock Hazard
Disconnect electrical power at the fuse box or circuit
breaker box before installing dishwasher.
Failure to do so can result in death or electrical shock.
Remove screw securing the electrical box cover. Remove
cover.
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector in
terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
3=
Power supply wire:
white
black
ground wire
Connect wires as follows using twist-on connectors sized to
connect direct wire to 16 gauge dishwasher wire.
Terminal box wire:
white
black
_ ground connector
4. Attach ground wire to the green ground screw.
A. Attach ground wire to green screw.
B. Attach white and black wires.