Remove the Top Cover and the Water Tank Chamber from the Base. Remove and discard the
protective foam on top of the Floater found inside the base.
Replace the water tank onto the base by aligning the Elechomes LOGO with the ON/OFF
button.
Fill the Water Tank Chamber with purified water or distilled water up to the Max Water Level
Line. Do not overfill. DO NOT ADD WATER TO THE BASE.
Plug into an electrical wall outlet.
Mist Strength adjust
Note: If there is water around the machine during use, it means that the humidity in the room is
too high. Please adjust to the appropriate mist strength.
4. Sleep mode
At any gear, long-press the on/off button for 3 seconds to enter the sleep mode. The
indicator light will go off. The humidifier will continue to run in the original gear. Press again
to exit the sleep mode.
3. Do not immerse the water box, water tank in hot water while cleaning.
4. There is an air inlet at the bottom of the machine. When cleaning, do not immerse the bottom
of the machine in water to avoid water entering into the machine from the air inlet and
damaging the machine.
5. External cleaning of humidifier: wipe the exterior surface with a soft wet cloth(the water
temperature should below 104°F.)
6. Do not use hard cleaning tools or chemical detergents when cleaning to avoid damaging the
parts.
7. Replace the water in the water tank on a regular basis to keep the product clean.
8. When the product is not in use for a long time, please pour out all the water and keep it dry.
1. When the machine is working, if you take out the water tank, it will automatically stop
spraying mist, and the indicator light will shine orange 10 times. After the water tank is put
back, you need to press the on/off button to turn it on again.
2. When the water level is low, it will automatically stop spraying mist, and the indicator light
will shine orange 10 times. After adding enough water to the water tank, you need to press
the on/off button to turn it on again.
Note: Lifting the water tank may not automatically shut down the humidifier. Even though there
is no water in the water tank, the machine is still spraying. Because the remaining water in the
base sink is not below the lowest water level. We recommend turning off the machine before
lifting the water tank to avoid spraying atomized water on the desktop.
Water Shortage
1. Clean the water tank, water box, and atomizing plate once every two weeks. Make sure to
unplug the device before cleaning.
2. Due to the higher water hardness in some areas, the surface of atomizing plate is prone to
accumulate scale faster. Users should wash them regularly with detergent, and clean the
inside of the water tank and the water box every week under the following instruction: Place
5 drops of dish soap on the surface of the atomizing plate. Pour in approximately 30ml of
water. Use a dish brush or sponge to clean the atomizing plate, and water box until all lime-
scale is removed. Drain the dirty water and rinse the device twice.
Maintenance
Note:
There is a fan inside the air outlet. Make sure that the fan remains dry all the time.
ON/OFF button Mist strength Indicator light
Press once High Blue
Press twice Medium Green
Press third time Minimum Orange
Press fourth time Product turn off
Cleaning Brush
Atomizing Plate
Float Valve
Air Outlet
1. Keep this unit out of reach of children and pets.
2. Do not put the product directly on the wooden floor to avoid dampness and causing
deformation.
3. Please place the product 2 meters away from furniture and electrical appliances to avoid
dampness.
4. When the room temperature is below zero, please pour out the water in the water tank and
water box to avoid the damage caused by ice.
5. Please don't put metal products, chemicals, or detergents into the water box, otherwise bad
atomization will occur.
6. When pouring out the water in the water box, please turn off the power supply and unplug
the power cord.
7. Never pour water into the mist nozzle and the air outlet.
8. When cleaning, make sure that water does not flow into the base.