
58516E
OWNER’S MANUAL
bestwayusa.com/support
Visit the Bestway YouTube channel

SAFETY INSTRUCTIONS
2
Visit the Bestway YouTube channel
OWNER’S MANUAL
58516E Sand Filter
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY - do not permit children to
use this product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK - Connect only to a grounding type
receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug is needed, use only identical replacement parts.
WARNING - The unit is provided with a ground-fault circuit-interrupter (GFCI).
To test the GFCI,push the test button. The GFCI should interrupt power. Push the reset
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed,
a ground current is flowing, indicating the possibility of an electric shock. Do not use this
pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer
than 5 feet (1.5 m) from the pool.
DO NOT BURY CORD -
Locate cord to minimize abuse from lawn mowers, hedge trimmers,
and other equipment.
WARNING -
To reduce the risk of electric shock, replace damaged cord immediately.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION:
This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of
being readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such that
it cannot be readily disassembled for storage. Please examine and verify all sand filter
components are present before use. Notify Bestway at the customer service address listed
on this manual for any damaged or missing parts at the time of purchase.
• THERMALLY PROTECTED MOTOR. CSA ENCLOSURE 3
• FOR USE WITH SWIMMING POOLS ONLY.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK
HAZARD,USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
WARNING:
RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING
TYPE RECEPTACLE.
CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO
NOT USE WITH PERMANENTLY-INSTALLED POOLS.
CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
CAUTION:
FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC
SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE WITH THE
INSTALLATION INSTRUCTIONS.
WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.
4) Do Not Touch Plug With Wet Hands.
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and
(
2
)
this device
must accept any interference received, including interference that may cause undesired
operation.
WARNING:
Any changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
WE SUGGEST NOT TO RETURN
THE PRODUCT TO THE STORE
QUESTIONS? PROBLEMS?
MISSING PARTS?
For FAQ, Manuals, Videos Or
Spare Parts, Please Visit
bestwayusa.com/support
V
i
s
i
t
w
w
w
.
b
e
s
t
w
a
y
u
s
a
.
c
o
m
/
s
u
p
p
o
r
t
f
o
r
h
e
l
p

3
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY - do not permit children to
use this product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK - Connect only to a grounding type
receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug is needed, use only identical replacement parts.
WARNING - The unit is provided with a ground-fault circuit-interrupter (GFCI).
To test the GFCI,push the test button. The GFCI should interrupt power. Push the reset
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed,
a ground current is flowing, indicating the possibility of an electric shock. Do not use this
pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer
than 5 feet (1.5 m) from the pool.
DO NOT BURY CORD -
Locate cord to minimize abuse from lawn mowers, hedge trimmers,
and other equipment.
WARNING -
To reduce the risk of electric shock, replace damaged cord immediately.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION:
This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of
being readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such that
it cannot be readily disassembled for storage. Please examine and verify all sand filter
components are present before use. Notify Bestway at the customer service address listed
on this manual for any damaged or missing parts at the time of purchase.
• THERMALLY PROTECTED MOTOR. CSA ENCLOSURE 3
• FOR USE WITH SWIMMING POOLS ONLY.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK
HAZARD,USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
WARNING:
RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING
TYPE RECEPTACLE.
CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO
NOT USE WITH PERMANENTLY-INSTALLED POOLS.
CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
CAUTION:
FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC
SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE WITH THE
INSTALLATION INSTRUCTIONS.
WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.
4) Do Not Touch Plug With Wet Hands.
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and
(
2
)
this device
must accept any interference received, including interference that may cause undesired
operation.
WARNING:
Any changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/ TV technician for help.

POOL SUCTION FITTING INSTRUCTIONS
When installing and using this equipment, basic safety precautions shall always be
followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW, AND UNDERSTAND ALL
INSTRUCTIONS AND WARNINGS.
- Any modification that increases the flow rate of the circulation system shall require
re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction
Outlet Fitting Assembly (SOFA) is not exceeded.
- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA
component shall be replaced before bathers are allowed to use the pool.
- Loose cover/grates shall be reattached before bathers are allowed to use the pool.
1. Replace suction fittings every 2 years.
2. The use of adhesives or other attachment methods that prevent access to suction piping
or SOFA components requiring periodic servicing is prohibited.
3. Refer to the following diagram for each SOFA component part instructions:
4. - Any field modification made to a SOFA not authorized by the manufacturer’s installation
instructions shall void the SOFA certification.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified as new SOFA.
- Cover/grates and all other SOFA components shall
be replaced at or before the end of their service life
and that service life begins the month and year in
which a SOFA component is installed with or
without water.
5. Winterizing instructions. Dry the suction fittings
completely, and store the product in a dry room at a
storage temperature of
15 ℃ ~ 40 ℃.
6. Use the screwdriver (not included) to disassemble
the suction fitting to clean or service.
- Cover/grate, including fasteners, shall be observed
for damage or tampering each operational day.
- Missing, broken, or cracked cover/grates shall be replaced before bathers are allowed
to use the pool.
- Loose cover/grates and associated components shall be reattached before bathers are
allowed to use the pool.
- SOFA components and fastener receptacles shall be clean and free of debris or
obstructions during installation of cover/grate and fasteners.
- Remember to hand-check cover/grate for snugness to the sump/ frame after
installation.
7. Before using the product, please check the integrity of the head of the suction fitting. If
the product is broken, cracked, or the color has significantly faded, please do not use it.
8. - All SOFAs shall be installed in accordance with the manufacturer’s installation
instructions.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified to the original SOFA.
- These SOFA-configuration specific flow ratings NOT be exceeded at any time the pool
is open to bathers.
- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the
finished surface of the pool in which the SOFA is installed.
9.
Please research and download General Certificate of Conformity through
www.bestwayusa.com
SAVE THESE INSTRUCTIONS
GFCI WARNING
WARNING: Risk of electric shock. The GFCI must be tested before each use.
WARNING: Do not use the pump if this test fails. For assistance, please visit
the support section on our website, www.bestwayusa.com.
F4030-03
F4030-02
F4030-01
4

POOL SUCTION FITTING INSTRUCTIONS
When installing and using this equipment, basic safety precautions shall always be
followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW, AND UNDERSTAND ALL
INSTRUCTIONS AND WARNINGS.
- Any modification that increases the flow rate of the circulation system shall require
re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction
Outlet Fitting Assembly (SOFA) is not exceeded.
- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA
component shall be replaced before bathers are allowed to use the pool.
- Loose cover/grates shall be reattached before bathers are allowed to use the pool.
1. Replace suction fittings every 2 years.
2. The use of adhesives or other attachment methods that prevent access to suction piping
or SOFA components requiring periodic servicing is prohibited.
3. Refer to the following diagram for each SOFA component part instructions:
4. - Any field modification made to a SOFA not authorized by the manufacturer’s installation
instructions shall void the SOFA certification.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified as new SOFA.
- Cover/grates and all other SOFA components shall
be replaced at or before the end of their service life
and that service life begins the month and year in
which a SOFA component is installed with or
without water.
5. Winterizing instructions. Dry the suction fittings
completely, and store the product in a dry room at a
storage temperature of
15 ℃ ~ 40 ℃.
6. Use the screwdriver (not included) to disassemble
the suction fitting to clean or service.
- Cover/grate, including fasteners, shall be observed
for damage or tampering each operational day.
- Missing, broken, or cracked cover/grates shall be replaced before bathers are allowed
to use the pool.
- Loose cover/grates and associated components shall be reattached before bathers are
allowed to use the pool.
- SOFA components and fastener receptacles shall be clean and free of debris or
obstructions during installation of cover/grate and fasteners.
- Remember to hand-check cover/grate for snugness to the sump/ frame after
installation.
7. Before using the product, please check the integrity of the head of the suction fitting. If
the product is broken, cracked, or the color has significantly faded, please do not use it.
8. - All SOFAs shall be installed in accordance with the manufacturer’s installation
instructions.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified to the original SOFA.
- These SOFA-configuration specific flow ratings NOT be exceeded at any time the pool
is open to bathers.
- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the
finished surface of the pool in which the SOFA is installed.
9.
Please research and download General Certificate of Conformity through
www.bestwayusa.com
SAVE THESE INSTRUCTIONS
GFCI WARNING
WARNING: Risk of electric shock. The GFCI must be tested before each use.
WARNING: Do not use the pump if this test fails. For assistance, please visit
the support section on our website, www.bestwayusa.com.
Installation Information label (copy)
Manufacturers name:
GOLEADER INDUSTRIES (JINHUA) CO., LTD.
Cover part number: F4030
Service life of the cover: 2 Years
Cover flow rating: 28 GPM
Installer needs to fill in the balance of the
information and permanently post it as near as
feasible to the pump control. Keep a copy of this
information with the other important pool related
documents.
Configuration and installed orientation:_________
Location:_______
Installed Date:_________
5

620mm
311mm
270mm
1
SPECIFICATIONS
PARTS REFERENCE OVERVIEW
Before assembling the sand filter, take a few minutes to become familiar with all the sand filter parts.
Filter Diameter
Effective Filter Area:
Max. Operating Pressure:
Working sand filter pressure:
Max. Water Temperature:
Sand:
Sand Size:
Sand Capacity:
270 mm
0.059 m
2
(0.635 ft
2
)
0.42 Bar (6 PSI)
<0.25 Bar (3.5 PSI)
35
˚C
Not included
#20 silica sand, 0.45-0.85 mm
Approximately 8.5 kg
x3
x2
x1 x1
A
B
A
B
B
B
-1
-2
6
A
x1
x1
x1
x1
x8
x11
x3
x2
x1
x1
x1
x1
x1
x1
x1
x2
x2
x1
x1
x1
B
x1
x1
x1
x1
x5
x5
x1
x2
x1
x1
x1
x1
x1
x1
x1
x2
x0
x0
x1
x0
NO.
19
19
18
18
17
-2
17
1
4 6
6
7
8
9
5
5
5
2
3
2
3
4
5
6
666 6
7
77
8
9
11
11
12
10
16
10
12
13
13
14
14
15
15
16
17
-1
17
17

A
B
B
B
A
A
B
B
A
B
B
B
A
B
B
B
c
c
Φ8mm
285mm
Bestway
V1.1
ASSEMBLY
CONNECT TO THE POOL
1. Carefully remove all components from the package and check to ensure nothing
is damaged. If equipment is damaged, immediately notify the retailer from where
the equipment was purchased.
2. The sand filter should be placed on solid, level ground, preferably a concrete
slab. Position the sand filter so the Ports and Control Valve are accessible for
operation, servicing and winterizing.
3. The sand filter must be vertically fixed on ground or a certain pedestal made of
wood or concrete before use to prevent the sand filter from accidental falling.
Fully assembled sand filter will exceed 18 kg. The mounting holes should be
8 mm in diameter and spaced 285 mm apart. Use two bolts and nuts with a
maximum of 8 mm in diameter to fasten the sand filter to the pedestal.
LOAD POOL-GRADE FILTER SAND/FLOWCLEAR™ POLYSPHERE.
NOTE: Use only special pool-grade filter sand, free of all limestone or clay: #20
Silica sand 0.45-0.85 mm, approximately one 8.5 kg bag should suffice. If you do
not use the recommended size filter sand, filtering performance will be reduced
and the sand filter may damaged, thereby voiding warranty.
NOTE: To avoid damaging the Skimmer when adding sand, pour some water into the Bottom Tank to submerse the
Skimmer on the Collector Hub.
NOTE: Sand/Flowclear™ Polysphere not included.
NOTE: Use 28 g (0.06 lbs) Flowclear™ Polysphere to replace 1 kg (2.20 lbs) sand.
7
(You will need a screwdriver.)
MAX
MIN
MAX
MIN
MAX
MIN
#20
0.45-0.85 mm
MAX
MIN
c
c
1
5 6 7
2 3 4

A
B
A
C
A
B
B
A
B
D
B
B
A
A
A
B
B
A
B
A
B
A
A
B
A
B
A
B
B
B
B
A
B
B
B
A
1 2
LOWERING OR DRAINING POOL WATER
V1.2
V2
8

A
D
C
OPERATION
GFCI TEST
Before switching on, please read the manual carefully.
STOP
Filter: This function is used to filter pool
water and should be positioned here 99%
of the time. Water is pumped through the
sand filter, where it is cleaned and
returned to the pool.
B
C
C
A
Closed: This function stops water
flowing between the sand filter and
the pool.
B
C
C
A
RESET
TEST
1 2
3
RESET
TEST
4
RESET
TEST
9
CONTROL VALVE OVERVIEW
WARNING: To prevent equipment damage and possible
injury, always switch off sand filter before changing the
Control Valve function. Changing valve positions while the
pump is running can damage the Control Valve, which may
cause personal injury or property damage.
How to Use the Control Valve:
Press down on the Control Valve handle and rotate to
desired function.
CONTROL VALVE FUNCTIONS
The Control valve is used to select 6 different filter functions:
Filter, Rinse, Circulate, Backwash, Closed and Drain.

Drain: This function drains water from the
pool; another filter by pass setting, water
is pumped and deposited out of Port D,
instead of returning it to the pool.
D
B
C
C
A
Backwash: This function is used to clean the
sand bed; water is pumped down through the
Collector Hub, upwards through the sand bed,
and deposited out of Port D.
D
B
C
C
A
Circulate: This function circulates pool water
by passing the sand filter; use this function if
the filter is broken to collect debris in the
Debris Screens.
D
B
C
C
A
Rinse: This function for initial startup, cleaning,
and sand bed leveling after Backwash; water is
pumped downwards through the sand bed, up
through the Collector Hub and deposited out of
the valve Port D.
D
B
C
C
A
10
NOTE:
• Be sure all provisions for wastewater disposal meet applicable local, state
or national codes. Do not discharge water where it will cause flooding or
damage.
• When the Control Valve is set to the Backwash, Rinse, or Drain position,
water will discharge from Port D on the Control Valve.
• Do not switch on or operate the sand filter with the Control Valve set to
the Closed function or it will seriously damage the sand filter.
•
Do not set the Control Valve between two functions, or it will lead to leaking.
• To avoid water leakage, insert the Port D Cap onto the Control Valve Port
D before operating the sand filter.
D
C
D
C
AIR RELEASE
Press down the control valve handle and wait untill the water flow from Port D to release the air.
NOTE:
It is important to repeat this operation every time you start the pump after winterizing, maintenance and backwashing
the sand bed.

SAND FILTER MAINTENANCE
CLEANING THE STRAINER
LOWERING OR DRAINING POOL WATER
STORAGE
FIRST TIME USE INSTRUCTIONS
Backwash and Rinsing must be performed to prepare the pump for its first use and to wash the sand.
CAUTION: DO NOT DRY RUN THE SAND FILTER
1. Press down on the Control Valve handle and rotate to the Backwash function.
2. Plug in and run the sand filter for 3-5 minutes, or until the water runs clear.
3. Switch off the sand filter and set the Control Valve to the Rinse function.
4. Switch on the sand filter and run the sand filter for 1 min. This circulates
water backwards through the sand filter and drains water out Port D.
5. Switch off the sand filter. Set the Control Valve to the Closed function.
6. Top up pool water if required.
IMPORTANT: This procedure removes water from the pool, which you’ll need to replace. Switch off the sand filter
immediately if water levels near the pool’s Inlet and Outlet valves.
1.6
0
5
10
15
20
23
1.4
1.2
1
0.8
0.6
0.4
0.2
0
psi
bar
1. Switch off the sand filter and set the Control Valve to the Closed function.
2. Replace the Debris Screens with Stopper Plugs to prevent water from escaping.
3. Remove the Strainer Cover by unscrewing it.
4. Take out the Strainer, remove any debris.
5. Put the Strainer back into position. Ensure the hole in the strainer is aligned.
6. Ensure the Seal Ring is in place. Secure the Strainer Cover back.
7. Remove the Stopper Plugs and insert the Debris Screens.
NOTE: The Strainer must be emptied and cleaned periodically.
A dirty or blocked strainer will reduce the performance of the sand filter.
1. Switch off the sand filter and set Control Valve to the Drain function.
2. Detach the Hose from the pool’s Port A and sand filter Port A and attach to Port D.
NOTE: Remember to replace the Debris Screen with Stopper Plug to prevent water from escaping.
3. Switch on the sand filter and press the “RESET” button to run the filter and remove the pool water.
WARNING: DO NOT DRY RUN THE SAND FILTER.
In areas that have freezing winter temperatures, pool equipment must be winterized to protect against damage. Allowing
water to freeze will damage the sand filter and void warranty.
1. Backwash the sand filter.
2. Drain the pool according to the pool owner’s manual.
3. Disconnect the two Hoses from the pool and the sand filter.
4. Completely pour the sand out of the tank and dry all components.
5. Store the sand filter in a dry location out of child’s reach.
11
CAUTION: You must ensure the sand filter is switched off and unplugged before
any maintenance begins or severe risk of injury or death exists. As dirt builds up in
the sand filter, the pressure reading on Pressure Gauge will increase. When the
Pressure Gauge is 0.25 Bar (3.5 PSI) or higher, or water flow to the pool is too low,
it is time to clean the sand. To clean the sand bed, follow all instructions outlined
previously in: Backwash and Rinsing.
NOTE: Pressure gauge is for maintenance purpose only, and the pressure gauge
value is just for reference, it should not be used as a precision instrument.
NOTE: We recommend you clean the sand bed once a month or less regularly
depending on how often the pool is used. Do not clean the sand too frequently.
1. Now the sand filter is ready for use. Set the Control Valve to the Filter function.
NOTE: To prevent the risk of electrical shock dry any excess water from yourself
and the sand filter.
2. Switch on the sand filter to run it.
NOTE: The sand filter has now started its filtering cycle. Check that water is
returning to the pool and take note of the filter pressure on Pressure Gauge.
Generally, the recommended sand filter pressure is less than 0.25 Bar (3.5 PSI)
when it is running.
RinsingBackwash

303021292426
For support please visit us at:
bestwayusa.com/support
©2022 Bestway Inflatables & Material Corp.
All rights reserved
Trademarks used in some countries under license from Bestway Inflatables & Material Corp., Shanghai, China
Exported by Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited
Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong
Distributed in North America by Bestway (USA) Inc., 3435 S. McQueen Road, Chandler, AZ 85286, United States of America
Tel: +86 21 69135588
www.bestwayusa.com
TROUBLESHOOTING
Sand Filter does
not operate
Sand is flowing
to the pool
No water flow
Excessive filter
pressure
Control Valve
leaks from the
port D
Connectors
leaks
Problems Probable Causes Solutions
- GFCI broken
- Sand is too small
- Move the control valve from the
backwash to the filter function
without stop the sand filter
- The level of the sand is too high
- The skimmer was broken
- Stopper plugs were not removed
- Air was not released
- The control valve is set to Closed
- The strainer is blocked
- Sand filter broken
- Dirty filter
- Calcified sand bed
- Insufficient backwashing
- The pressure gauge was broken
- Control Valve was set between
two functions
- The gasket was broken
- O-ring on the hose connection
was broken
- Loose Hoses
- For assistance, please visit the support section on our
website, www.bestwayusa.com.
- Recommend 0.45 mm to 0.85 mm #20 silica sand
- Stop the sand filter every time set the control valve
- Check if the level of the sand is between the
marked “MAX” and “ MIN” on the hub
- Replace the skimmer
- Remove the stopper plugs and insert the debris
screens
- Release the air
- Set to filter function
- Clean the strainer
- Call for service
- Backwash
- Inspect sand and change if necessary
- Backwash until effluent runs clear
- Replace the pressure gauge
- Set to one function
- Replace the gasket
- Replace the o-ring
- Tighten them
GFCI LED flash
- Plug may be loose in the socket; the
internal metal part of the plug doesn't
guarantee a secure connection
- Replace the socket
- Replace the pump
