Blaze Outdoor Products Instructional Book
Page | 15
GAS LEAK WARNINGS
Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure ONLY USE A PROFESSIONAL.
NEVER USE THE GRIDDLE WITHOUT FIRST LEAK TESTING THE GAS CONNECTIONS INCLUDING ALL
OF THE VALVES, FITTINGS, LINES ETC. (ALL GAS CONNECTIONS SHOULD BE CHECKED)
WARNING: DO NOT USE OPEN FLAME TO CHECK FOR LEAKS. USE OF AN OPEN FLAME
COULD RESULT IN A FIRE, EXPLOSION AND BODILY HARM.
DO NOT SMOKE WHILE PERFORMING THE LEAK TEST. Any open flame will ignite the gas.
To prevent fire or explosion hazard, Perform leak test outdoors only.
Check to ensure that flexible hoses do not have any cuts and wear that may affect the safety before each use.
Only the factory supplied hose and regulator must be used. Use only replacement regulator and hose assemblies
specified by BLAZE OUTDOOR PRODUCTS.
Checking for Gas Leaks
Perform a leak test before each use whether the gas supply cylinder has been disconnected or not. In addition,
whenever the gas cylinder is connected to the regulator or whenever any part of the gas system is disconnected or
replaced, perform a leak test.
As a safety precaution, remember to always leak test your appliance outdoors in a well-ventilated area. Never
smoke or permit sources of ignition in the area while doing a leak test. Do not use a flame, such as a lighted
match to test for leaks. Use a solution of soapy water.
Prepare a leak testing solution of soapy water by mixing in a spray bottle one part liquid soap to one
part water.
Make sure all the control knobs are in the OFF position.
Turn on the gas.
o
On Natural Gas systems, turn the main feed valve to the appliance.
o
On LP systems, turn the cylinder valve knob counter clockwise one turn to open.
Apply the leak-testing solution by spraying it on joints of the gas delivery system. This includes all
valves, pipe connections, joints, lines and every point from the gas source to the burners.
Blowing bubbles in the soap solution and/or there is a faint gas smell (Typically Gas has an Egg Smell)
indicates that a leak is present. Do not attempt to ignite the grill.
Turn all control knobs back to the full OFF position.