Thermal 2-Pole Breaker
(PDUMNH32HV)
A B
4
2. Features
(PDUMNH30HV & PDUMNH32HV): The Digital Load
Meter may be set using the Meter Select switch to display
the PDU’s total connected load (all 16 outlets-both LEDs
illuminated), or the load carried by either the upper bank
(Bank 1 LED illuminated) or lower bank (Bank 2 LED
illuminated) of 8 outlet receptacles. If you press and hold
the mode selection switch A for 4 seconds, the unit’s IP
address will display on the meter B. Note: If no IP address is
assigned (default), “no address” will display, one letter at a
time. If an IP address is assigned, it will display one digit at a
time, with dashes (-) representing the dots (.) in the address.
Output Circuit Breakers: Two circuit breakers (one
per outlet bank) protect connected equipment against
dangerous system overloads. If the total load on either of the
PDU’s outlet banks exceeds 20 amps, the associated circuit
breaker will trip, cutting power to the entire outlet bank.
Reduce the load on the outlet bank by unplugging some
equipment; then switch the circuit breaker ON to restore
power.
Longer 1U Mounting Brackets: Use these brackets to
mount the 1U PDU horizontally in a standard rack or rack
enclosure. The mounting depth can be adjusted by attaching
the brackets to different positions on the PDU.
Shorter 0U Mounting Brackets: Use these brackets
to mount the PDU in a 0U rack, wall or under-counter
configuration for 1U PDU models.
2U Mounting Brackets: Use these brackets to mount the
2U PDU horizontally in a standard rack or rack enclosure, or
in an under-counter configuration.
C14 Plug-Lock Insert Sleeve (Optional): Use the included
plastic sleeves to secure C13 power cords to C14 inlets. Fit
the sleeve over the end of the cord, making sure the pull-
tabs remain outside the cord and the fit is secure. To unplug
equipment properly, grip both the cord and the insert’s tabs
at the same time and pull.
C20 Plug-Lock Insert Sleeve (Optional): Use the included
plastic sleeves to secure C19 power cords to C20 inlets. Fit
the sleeve over the end of the cord, making sure the pull-
tabs remain outside the cord and the fit is secure. To unplug
equipment properly, grip both the cord and the insert’s tabs
at the same time and pull.
Magnetic, 2-Pole Branch-Rated
Breaker (PDUMNH30HV)
21-03-421-933684.indb 421-03-421-933684.indb 4 4/5/2021 1:26:33 PM4/5/2021 1:26:33 PM