2.
If the air 󰘰lters are severely dirty, you
can also wash the air 󰘰lters using warm
water under 40ºC and liquid dishwashing
detergent. Rinse 󰘰lter and washing up
liquid thoroughly.
Gently shake excess water from the 󰘰lter.
Be sure that the 󰘰lter is thoroughly dry
before replacing.
3.
Press the 󰘰lter reset button “
” after
having cleaned the 󰘰lters.
Be sure that the 󰘰lter is thoroughly
dry before replacing.
8.3
Winter Storage
If the portable air conditioner will not be
used for an extended period of time:
1.
Drain the water collection tank completely
and leave the bottom drain cap and
rubber plug for long enough to allow any
residual water to drain out. Once the tank
is completely drained and no more water
󰘱ows out, reinstall the rubber plug and
cap.
2.
Remove and clean the 󰘰lter, allow it to
dry completely, then reinstall it.
3.
Store the portable air conditioner in
a cool, dry location, away from direct
sunlight, extreme temperature, excessive
dust, and well ventilated.
Before using the portable air conditioner
again:
1.
Make sure the air 󰘰lter and drain cap are
in place.
2.
Check the cord to make sure it is in good
condition, without cracks or damage.
3.
Install the portable air conditioner as
described in the operating instructions.
9.
TROUBLE SHOOTING
This list includes common issues that are
not the result of defective workmanship or
materials in this appliance.
Portable air conditioner will not operate.
Wall plug disconnected. Push plug 󰘰rmly
into wall outlet.
House fuse blown or circuit breaker
tripped. Replace fuse with time delay type
or reset circuit breaker.
The unit is OFF. Turn the unit ON and set
to desired setting.
Fault code P1 appears in the display
window. Drain water as described in
7.3 Drainage Section.
Room Temperature lower than the set
temperature (Cool Mode) or Room
Temperature higher than the set
temperature (Heat Mode). Reset the
temperature.
Air from unit does not feel cold enough.
Room temperature below 16ºC. Cooling
may not occur until room temperature
rises above 16ºC.
Reset to a lower temperature.
Compressor shut-o󰘯 by changing modes.
Wait approximately 4 minutes and listen
for compressor to restart when set in the
COOL mode.
Portable air conditioner cooling, but
room is too warm.
If ice forms on the cooling coil located
behind decorative front, the outdoor
temperature is likely to be below 16ºC.
Air 󰘰lter may be dirty. Clean 󰘰lter. Refer
to section 8 “Care and Cleaning”.
If ice forms on cooling coil behind
decorative front. Temperature is set too
low for night time cooling. To defrost
the coil, set to Fan mode. Then, set
temperature to a higher setting.
Exhaust duct not connected or blocked.
See 5.1 Exhausting Hot Air Section.