Economy Series Installation Details:
MODELS
1900E, 1900ENV
CABINET: Be sure that the cabinet bottom is level, side to side and front to rear.
For the Vented Unit (1900E) you will need to cut an 8” x 8” hole in the bottom of the cabi-
net, 3/4” in from the rear wall and on center line. For the Non-Vented model (1900ENV)
there is no need for a duct pipe cut out. Shelves and top to be cut to clear 7” round pipe to
line up with the bottom cabinet cut out. Also, cut holes for electrical wires for both Vented
and Non-Vented.
ELECTRICAL: Bring enough wire into cabinet to reach in front of vent pipe. Enter cabinet
3 1/4” left of center and 1 1/2” from wall for vented and non-vented units. Remove
electrical box cover before mounting hood. Units are to be hard wired
. It is not
recommended to add a power-cord. Adding a power cord can loosen existing wires
inside junction box causing electrical failure.
NOTE: Be sure to remove black electrical tape that holds the damper blades closed.
MOUNTING: Insert canopy below the cabinet, being sure your vent opening and electrical
cut outs line up with cabinet cut outs. Use the Key Hole mounting holes to secure the
canopy. After hood is mounted attach house wires to leads in the hood. Secure locknut to
conduit and check wiring for compliance to local building codes.
FINISH: Replace electrical box cover. Connect duct and tape all joints. Install 40 Watt bulb
and replace Filter. (bulbs not included)
WARNING:
To reduce the risk of fire or electrical shock DO NOT use the “E” series with any solid-state
speed control device.