Description orders for model HRH3001U HRH3003U HRH3004U
Automatic activation control function of the sensor:
There are 5pcs sensor buttons,1pc remote control signal lamp(remote controller included), 2pcs stainless steel grease boxes,
2pcs stainless steel baffle filters and 2pcs led bulbs( 12V/1.5W).
A0 button: Remote control signal lamp
A1 button: Power( on/off)
A2 button: LED bulb
A3 button: Display screen
A4 button: Time Delay. A5 button: Low speed
A6 button: High speed
A4 button equip with Max 15 minutes after power off, A1 button( on/off) control to directly started or off.
Open The Fan
Keep your hood working during the cooking, and keep vantilating.
Press A1 button, then A3 display screen open.
Button A5 and A6 activates,high speed (F4),average speed(F3), low speed(F2), quiet speed(F1).
Control Panel Layout and Button Disposition
Close The Fan
Off time-delay function just could close the fan, not affected the lamplight setting.
15 minutes time-delay
When fan working, press A4 button, digital screen will blink several seconds, default setting is 1minute,after that, will shut off
automatically.
During fan working, if you need to adjust time-delay function,press A4 button one time, will blink for a few seconds, press A6
Loading ...