FIGURE 6
MODEL 9417DNM
Lamp & Vent operate together
MODEL 9417DNM
Lamp & Vent operate separately
MODEL 9420WHC
Lamps operate together
MODEL 9420WHC
Lamps operate separately
MODEL 9425WHC
Vent & Heat operate together –
Light separately
MODEL 9425WHC
Light, Vent & Heat operate separately
MODEL 9425WHC
Light & Vent operate together –
Heat separately
MODEL 9425WHC
Lamps operate together –
Vent separately
WHITE to
WHITE / GRAY
120 VAC LINE IN
GROUND
BLACK
BLACK
WHITE
to WHITE
BLACK to
RED & BLUE
GROUND
SWITCH OR TIMER
RED
VENT
WHITE to
WHITE / GRAY
120 VAC LINE IN
BLACK
BLACK
WHITE to
WHITE
BLACK TO BLUE
RED TO RED
GROUND
HEAT
DUAL CONTROL
GROUND
WHITE to
WHITE / GRAY
120 VAC LINE IN
GROUND
BLACK
BLACK
LIGHT
BLACK to BLACK
GROUND
HEAT
RED
DUAL CONTROL
RED to RED
WHITE to
WHITE
120 VAC LINE IN
GROUND
LIGHT
DUAL CONTROL
3 WHITE / GRAY WIRES
VENT & HEAT
BLACK to BLACK,
& YELLOW
RED to RED
& BLUE
GROUND
RED
WHITE to
WHITE
BLACK
120 VAC LINE IN
GROUND
LIGHT
& VENT
DUAL CONTROL
3 WHITE / GRAY WIRES
HEAT
BLACK to
BLACK, & BLUE
RED to RED
& YELLOW
GROUND
RED
WHITE to
WHITE
BLACK
120 VAC LINE IN
GROUND
VENT
DUAL CONTROL
3 WHITE / GRAY WIRES
HEAT & LIGHT
BLACK to
BLUE
RED to RED,
BLACK &
YELLOW
GROUND
RED
WHITE to
WHITE
BLACK
HEAT
120 VAC LINE IN
GROUND
3 BLACK WIRES
3 WHITE
WIRES
LIGHT
BLACK
3-FUNCTION CONTROL
WHITE to WHITE / GRAY
VENT
BLACK to BLACK
BLACK to YELLOW
RED to RED
RED
GROUND
WHITE to WHITE
RED to BLUE
WHITE to
WHITE / GRAY
120 VAC LINE IN
GROUND
BLACK
BLACK
WHITE to
WHITE
BLACK to
BLACK
& RED
GROUND
SWITCH OR TIMER
Loading ...
Loading ...