Casio MTG-512SC

User Manual

For MTG-512SC.

PDF File Manual, 3 pages, Download pdf file

USER’S GUIDE 2713
1
About This Manual
Button operations are indicated using the letters shown
in the illustration.
Each section of this manual provides you with the
information you need to perform operations in each
mode. Further details and technical information can be
found in the “Reference” section.
General Guide
Press C to change from mode to mode.
In any mode, press B to illuminate the display.
Timekeeping
Use the Timekeeping Mode to set and view the current time and date.
In the Timekeeping Mode, press D to toggle the display between the date screen
(day of the week, month, and day) and the time screen (hour, minutes, and
seconds).
This watch features separate digital and analog timekeeping. Note that the digital
time and analog time are independent of each other, and must be set separately.
Month – Day
Second
s
Day of week
Minutes hand
AM/PM
indicator
Press .
Date Screen Time Screen
Hour hand
Hour : Minutes
To set the digital time and date
1. In the Timekeeping Mode, hold down A until the seconds start to flash, which
indicates the setting screen.
2. Press C to move the flashing in the sequence shown below to select other
settings.
Seconds DST on/off City code Hour Minutes
Day Month Year 12/24-Hour Format
3. When the setting you want to change is flashing, press D and/or B to change it
as described below.
Timekeeping Mode e-DATA MEMORY
Mode
World Time Mode Alarm Mode Countdown
Timer Mode
Stopwatch
Mode
Hand Setting
Mode
Press .
Pressing D while the seconds are in the range of 30 to 59 resets them to 00 and
adds 1 to the minutes. In the range of 00 to 29, the minutes are unchanged.
For full information on city codes, see the “City Code Table”.
4. Press A to exit the setting screen.
Daylight Saving Time (DST)
Daylight Saving Time (summer time) advances the time setting by one hour from
Standard Time. Remember that not all countries or even local areas use Daylight
Saving Time.
To toggle the Timekeeping Mode time between DST and Standard Time
1. In the Timekeeping Mode, hold down A until the
seconds start to flash, which indicates the setting
screen.
2. Press C to move the flashing to the DST On/Off
setting.
3. Press D to toggle between Daylight Saving Time
(
ON displayed) and standard time (OFF displayed).
4. Press A to exit the setting screen.
The DST indicator appears on the display when Daylight
Saving Time is turned on.
To change this setting
Seconds
DST on/off
City code
Hour, Minutes, Year, Month, Day
12/24-Hour format
Perform this button operation
Press D to reset to 00.
Press D to toggle between DST on (ON displayed)
and off (
OFF
displayed).
Use D to scroll through the available codes
(time zone) to the east or B to scroll to the west.
Use D (+) or B (–) to change the setting.
Use D to toggle between 12-hour (12H) and
24-hour (24H) timekeeping.
DST indicator
e-DATA MEMORY
You can use the watch’s e-DATA MEMORY to store e-
mail addresses, Web page URLs, and other text data.
You can also use a password to limit access to e-DATA
MEMORY contents.
You can input up to 63 characters for each e-DATA
MEMORY record. See “e-DATA MEMORY
Management” for information about the number of
records you can store.
All of the operations in this section are performed in the
e-DATA MEMORY Mode, which you enter by pressing
C.
To create a new e-DATA MEMORY record
1. In the e-DATA MEMORY Mode, press D and B at the
same time to display the remaining memory screen
.
If
^% is shown for remaining memory, it means that
memory is full. To store another record, you will first
have to delete some of the records stored in memory.
2. Hold down A until the flashing cursor (
p
) appears on
the display, which indicates the setting screen.
3. Input the text you want.
When inputting the text, use D (+) and B (–) to
cycle through characters at the current cursor
location, and C to move the cursor to the right. See
“Inputting Text”.
4. Press A to store your data and return to the e-DATA
MEMORY record screen (without the cursor).
The text can show only six characters at a time, so
longer text scrolls continuously from right to left. The
last character is indicated by the symbol
< after it. Press
A to stop and restart scrolling.
Records are stored in memory in the sequence they are
created.
To recall e-DATA MEMORY records
In the e-DATA MEMORY Mode, use D to cycle through e-DATA MEMORY records as
shown below.
Remaining
memory
screen
Record 1
Record 2
Password
setting
screen
Alternates
(1 second)
Alternates
(1 second)
Remaining Memory Screen Password Setting Screen
The Remaining Memory screen shows remaining memory as a percent value.
Memory is full when the percent value shows 0%.
You can use the Password Setting screen to register, edit, or delete your password.
See “Using a Password to Protect e-DATA MEMORY Data” for more information.
To edit an e-DATA MEMORY record
1. In the e-DATA MEMORY Mode, use D to display the record you want to edit.
2. Hold down A until the flashing cursor appears on the display.
3. Use C to move the flashing to the character you want to change.
4. Use D (+) and B (–) to change the character.
5. After making the changes you want, press A to store them and return to the
e-DATA MEMORY record screen.
To delete an e-DATA MEMORY record
1. In the e-DATA MEMORY Mode, use D to display the record you want to delete.
2. Hold down A until the flashing cursor appears on the display.
3. Press B and D at the same time to delete the record.
The message
CLR appears to indicate that the record is being deleted. After the
record is deleted, the cursor appears on the display, ready for input.
4. Input data or press A to return to the e-DATA MEMORY record screen.
Tex t
Remaining memory
New Data Screen
Loading ...
Loading ...

Other documents for Casio MTG-512SC

The following documents are available:

Specifications