201157 - 3650W DUAL FUEL ELECTRIC START GENERATOR
OPERATION
24
NOTICE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
Starting the Engine: Propane (LPG)
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Connect LPG hose to generator and LPG cylinder. See “Add
Fuel: Propane (LPG) section of the manual.
4. Fully open the valve on the LPG cylinder.
5. Turn fuel select dial to the “PROPANE RUN” position.
Electric Start
6. Move the choke lever to the “CHOKE” position.
7. Press the ignition switch to the “START” position for 2-3
seconds.
8. Move the choke lever to the “RUN” position.
9. Press and hold the ignition switch in the “START” position for
up to 5 seconds or until started.
NOTICE
If the engine is cranked longer than 5 seconds, the engine can
flood and will not start.
10. If engine does not start, wait 10 seconds and repeat step 9.
11. When the engine starts, move choke lever to the “RUN”
position if in the “ CHOKE” position.
12. Plug in devices