Technical indicators
EN
Copyright © Qingdao Hantek Electronics Co., LTD Tablet1000 data manual
3
2 Technical indicators
All technical specifications are applicable to the Tablet1000 series oscilloscopes. For
detail, check the end of this chapter. To verify that an oscilloscope meets the technical
specifications, it must first meet the following conditions:
The oscilloscope must have been operating continuously for at least 20 minutes at
the specified operating temperature.
If the operating temperature varies by more than 5 degrees Celsius, the
"self-calibrate" operation must be performed, which can be find under the Utility
menu.
The oscilloscope must be within the ex-factory calibration period.
All technical specifications are guaranteed to meet requirements except those marked
"typical".
Technical indicators
Model
Bandwidth
Sampling rate
TO1112 (C/D)
110 MHz
250MSa/S
TO1152 (C/D)
150 MHz
1GSa/S
TO1202 (C/D)
200 MHz
1GSa/S
TO1252 (C/D)
250 MHz
1GSa/S
TO1204 (C/D)
200 MHz
1GSa/S
TO1254 (C/D)
250 MHz
1GSa/S
TO1154 (C/D)
150 MHz
1GSa/S
TO1204AUTO
200 MHz
1GSa/S
TO1254AUTO
250 MHz
1GSa/S
TO1154AUTO
150 MHz
1GSa/S
Horizontal system
Horizontal scale range
2ns/div ~ 100s/div 1, 2, and 5 steps
Incremental time accuracy
(Full bandwidth)
Single, "sampling" mode
± (1 sampling interval +100ppm× reading +0.6ns)
> 16 times on average
± (1 sampling interval +100ppm× reading +0.4ns)