INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to TABLE 1. (All calculation in inches).
- FOR BUILT-IN / INSERT -
TABLE 1
A = Height of Floor to Ceiling
B = Height of Floor to Counter Top
(Standard: 36”)
C = Height of Counter Top to Wood Frame
Bottom (Recommended 26” to 30”)
D = Height of Wood Frame
SAFETY WARNING
HOOD MAY HAVE SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING
ANY PARTS FOR INSTALLING, CLEANING, OR SERVICING.
BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY
OCCUR. USING HAND TOOLS IS RECOMMENDED. DO NOT OVER TIGHTEN SCREWS.
MAKE SURE TO PREVENT ANY DEBRIS FROM ENTERING THE VENT OPENING TO
AVOID DAMAGE OR MALFUCTION.
INSERT INSTALLATION
Before Installation
1. Read any provided document(s).
2. Test the range hood by temporarily connecting it to an outlet and turning ON the fan and lights.
3. If you run into any problems, contact KOBE Range Hoods.
Venting Requirements
4. The range hood has top 6” round exhaust (default).
5. Decided the location of the venting pipe from the hood to the outside. A straight, short vent run
will allow the hood to perform more efficiently. Try to avoid elbows, transitions, and long run as
much as possible as this may reduce the performance of the hood. Make sure that the duct work
leads to the outside.
6. It is recommended to use metal/aluminum duct/pipe with a uniform size (ex. 6” round pipe from
range hood to the outside).
7. If an elbow is necessary, a minimum of 12” straight run is necessary before the elbow.