Duct Cover Installation
4. Mark the position of the duct cover-mounting bracket. Use reference E from Table 2 for
references. Attach and secure duct cover-mounting bracket with two screws (not
provided). Refer to Figure 27. NOTE: Inner duct cover will cover the mounting bracket.
5. Connect electrical wires. Refer to “Wiring to Power Supply” on Page 17.
6. Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood.
Refer to Figure 28.
Figure 27 Figure 28
7. Adjust the height of the inner duct cover to the duct cover-mounting bracket. Secure the
inner duct cover with two (4x8 mm) screws (provided) as shown in Figure 29.
Figure 29
8. Fasten outer duct cover to multi vent exhaust on the hood with four (4x8 mm) screws
(provided).
Attach Together