4. Installation
2. Eaves Installation
After ensuring sucient clearance exists for the mounting ange and ducting (gure 1), cut a circular hole
165mm Ø, maintaining adequate clearances. The eave sheeting must be reinforced.
Pre-drill mounting ange recess (gure 4).
If access to the eave space is restricted, before xing the mounting ange to the eave, preassemble the
mounting ange, PVC pipe, bell-mouth adaptor and exi-duct, then feed up into roof space. Remember to run
power cord through the assembly and out the slotted PVC pipe wall (gure 4).
Fit the fan module to mounting ange by placing in position, rotating clockwise to engage bayonet ngers then
secure by screwing in locking screw (while holding fan module rmly in the fully clockwise position).
Ensure that one of the three
bayonet ngers is accessible for
securing locking screw
Bell-mouth Adaptor
Roof Cladding
Locking Screw
Pre-drill mounting
ange recess and secure
to reinforced eaves
sheet using #8 self
tapping screws
Wall
Eaves
Top Plate
150mm Ducting
Roof Frame/Truss
Figure 4
Please refer to page 12 (Figure 6)