English
Wiring
<Methodofmountingconduit>
1) Passwiresthroughtheconduitandsecurethemwithalocknut.
2) Aftercompletingthework,reattachtheconduitmountingcoverandtheprotectionplatetoitsoriginalposition.
1 2 3
1 2 3
Power supply
terminal block
Shape wires so
that the service
lid and stop
valve cover fit
securely.
Use the specified wire type and
connect it securely.
Conduit
mounting
plate
Conduit
1/2 inch
(21.3mm)
Lock nut
Observethenotesmentionedfollowingwhenwiringtothepowersupplyterminalblock.
Precautionstobetakenforpowersupplywiring.
CAUTION
•Whenconnectingtheconnectionwirestotheterminalblock
usingasinglecorewire,besuretoperformcurling.
Problemswiththeworkmaycauseheatandres.
Strip wire end
to this point.
Excessive strip length
may cause electrical
shock or leakage.
Good Wrong
•Ifthestrandedwiresmustbeused,makesuretousethe
roundcrimp-styleterminalforconnectiontothepower
supplyterminalblock.Placetheroundcrimp-style
terminalsonthewiresuptothecoveredpartandsecurein
place.
Stranded wire
Round crimp-style
terminal
3) Pullthewireandmakesurethatitdoesnotdisconnect.Thenxthewireinplacewithawirestop.
Stripping wire at terminal block
Good Wrong
01_EN_3P300674-1B.indd 10 8/28/2012 5:51:00 PM