Vevor EZL-EH-30S-U Alcohol Still, 9 Gal 30L Water Alcohol Distiller, Home Distillery Kit include Stainless Steel Tube & Pump & One-way Exhaust Valve & Thermometer 30-120℃

USER MANUAL - Page 14

For EZL-EH-30S-U.

PDF File Manual, 20 pages, Read Online | Download pdf file

EZL-EH-30S-U photo
Loading ...
Loading ...
Loading ...
- 13 -
1. After installing the product, the temperature control switch knob is in the position shown in
the picture, ready for work.
2. Turn on the power, the green light is on, indicating that the product enters the standby
state.
3. Turn the temperature control switch knob clockwise, the yellow light is on, indicating that
the heating plate is working and heating starts, and turn the temperature control switch knob
to the required temperature.
4. After the temperature reaches the set temperature, the yellow light goes out, and the
automatic constant temperature is within the set temperature range.
5. After the work is completed, turn the temperature control switch knob to turn off, and
unplug the power.
Equipment Cleaning and Maintenance
1.The distiller needs to clean the inside of its pot, condenser and other components before
or after each use, and drain all the impurities inside it. After we have used the distilled
water dispenser, we need to clean it every once in a while. Pay attention to cleaning the
inner wall of its evaporation pot, the inner wall of the condenser, the surface of the
condenser tube and the scale in the outlet pipe of the condenser. Avoid affecting its use.
2.Before starting the machine, please check whether the voltage of the power supply used
is consistent with the voltage of the machine used, to ensure that the contact between the
socket and the machine meets the safety standards, and the leakage protection switch and
ground wire are installed, and everything must meet the electricity requirements.
3. The bottom of the product is equipped with electrical parts. Do not place the instrument in
water or places with excessive humidity when in use.
4. During the use of the distilled device, pay attention to observe the liquid level. If the liquid
level continues to drop, first turn off the power and check whether the return water is
unblocked. If the water is cut off or the water level is lower than the heating tube, it will
cause the heating tube to explode and leak electricity, which will cause serious danger. If
the water level continues to rise and boil, first turn off the power and water source. The
preliminary judgment is that the heating tube is burnt out, and the professional should be
notified for maintenance.
5.For some newly purchased stills, we need to clean them first, and pass electricity for more
than 2 hours to evaporate until the obtained distilled water meets the requirements.
Loading ...
Loading ...
Loading ...