The microprocessor is able to signal three different kinds of failure by flashing the “Limiter”
red LED on the amplifier panel before the lighting up of the “Power status” green LED. The
three types of failure are: WARNING: a non severe error or auto-ripristinate malfunction
is detected and the performance of the speaker is not limited. LIMITATIONS: an error is
detected and the performance of the speaker is limited (the sound level is reduced by 3 dB).
This does not affect the operation of the speaker since it continues to operate. However, it
is necessary to call the service centre to solve the issue. FAILURE: a severe malfunction is
detected. The speaker switches to “mute”.
FLASHING INDICATION: 1 or 2 >Warning 3 or 4 >Limitation from 5 to 8 >Failure.
In case of failure, the “Ready” green LED remains off.
Perform the checks listed below:
- check if the speaker is properly connected to the power supply
- make sure that the power supply is of correct voltage
- check that the amplifier is not overheated
- disconnect the speaker from the mains power supply, wait for a few minutes and connect
it again. If after these tests the red “LIMITER” LED is still on, please contact an authorised
service centre.
FAILURE INDICATION
AND SAFETY
!
VOLTAGE SETUP
(RESERVED TO THE RCF SERVICE CENTRE)
ST 12-SMA II
200-240 Volt, 50 Hz SETUP: FUSE VALUE T 1.6 A 250 V
100-120 Volt, 60 Hz SETUP: FUSE VALUE T 3.15 A 250 V
ST 15-SMA II
200-240 Volt, 50 Hz SETUP: FUSE VALUE T 3.15 A L 250V
100-120 Volt, 60 Hz SETUP: FUSE VALUE T6.3 A L 250V