4
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
- All Other Markets:
NOTE:
* - Measure burner operating pressure at the gas control outlet test point with burner
operating at High setting. Operating pressure is ex-factory set through appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to Gas Conversionsection for details).
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Input Rating (N.H.G.C.) 72MJ/hr 90MJ/hr 72MJ/hr 90MJ/hr
Supply Pressure 1.13 - 3.40kPa 2.75 - 4.50kPa
Burner Operating Pressure (*) 0.76kPa 0.60kPa 2.5kPa 2.4kPa
Gas Connection ¾BSP Male
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Heat Input (nett)
Nominal
18.5kW 23kW 18.5kW 23kW
Pilot
190W 140W
Gas Rate (nett)
Nominal
1.96m
3
/hr 2.43m
3
/hr 1.44kg/hr 1.79kg/hr
Pilot
0.02m
3
/hr 0.01kg/hr
Supply Pressure 20mbar 37mbar
Burner Operating Pressure (*) 7.5mbar 6.0mbar 25.7mbar 25.5mbar
Gas Connection
3
/
4
BSP Male
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Input Rating (N.H.G.C.) 72MJ/hr 90MJ/hr 72MJ/hr 90MJ/hr
Supply Pressure 1.13 - 3.40kPa 2.75 - 4.50kPa
Burner Operating Pressure (*) 0.76kPa 0.60kPa 2.5kPa 2.4kPa
Gas Connection ¾BSP Male
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Input Rating (N.H.G.C.) 72 MJ/hr 90 MJ/hr 72 MJ/hr 90 MJ/hr 72 MJ/hr 90 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.76 kPa 0.60 kPa 2.5kPa 2.4kPa 2.5kPa 2.4kPa
Gas Connection ¾BSP Male