Midea MLTG45N4BWW 7.0 Cu.Ft. Smart Tumble Dryer

7.0 Cu.Ft. Smart Tumble Dryer User Manual - Page 12

For MLTG45N4BWW.

PDF File Manual, 102 pages, Read Online | Download pdf file

MLTG45N4BWW photo
Loading ...
Loading ...
Loading ...
DUCTING REQUIREMENTS
RecommendedUse only for short-run
installation
Weather Hood
Type
4" DIA
4" DIA
4"
4 inch. (10.2 cm)
4" DIA
2-1/2"
2.5 inch. (6.4 cm)
No. of 90°
elbows
Rigid MetallicRigid Metallic
090 ft. (27.4 m)60 ft. (18.3 m)
160 ft. (18.3 m)45 ft. (13.7 m)
245 ft. (13.7 m)35 ft. (10.7 m)
335 ft. (10.7 m)25 ft. ( 7.6 m)
Manometer measurements
The static pressure in any exhaust system for best results shall be between
0.3 to 0.8 inches of water column, and cannot be less than 0 under any
circumstances. with installed duct of 4 inch diameter. Measurement must
be done with the empty dryer working with a manometer at the point
where the exhaust duct connects to the dryer. A no-heat setting should be
used. Lint filter must be clean.
If this new dryer is installed into an existing exhaust system you must make
sure:
The exhaust system meets all local, state, and national codes.
That a flexible plastic duct is not used.
To inspect and clean all lint buildup from inside the existing duct.
The duct is not dented or crushed.
The exhaust hood damper opens and closes freely.
Dryer
Safety
Operation
Requirements
Parts and
Features
Installation
Instructions
Dryer Use
Appendix
Dryer Care
Troubleshooting
12
Loading ...
Loading ...
Loading ...