JET JB-10R Portable Plate Beveling Straight and Round Bevels

Manual - Page 7

For JB-10R.

PDF File Manual, 20 pages, Download pdf file

Loading ...
Loading ...
Loading ...
7
5.0 Setup and assembly
5.1 Shipping contents
Inspect contents for shipping damage or part
shortages. If either is found, contact your
distributor. Do not discard carton or packing
material until machine is set up and running
satisfactorily.
1 Plate Beveling machine
1 Push plate
1 Pedestal
1 Prop stand (Model JB-10R only)
5 Carbide blade inserts, preinstalled *.
1 Operator’s manual (not shown)
1 Product registration card (not shown)
* Model JB-10P is provided with straight carbide
blade inserts (preinstalled) for making flat bevels.
* Model JB-10R is provided with R5 radiused
inserts (preinstalled) and R3 radiused inserts for
making rounded bevels.
5.2 Setup options
The Plate Beveling Machine may be used in
portable or hand-held position, as shown in Figure
8-2; or mounted to a workbench in fixed position as
shown on cover photo. If mounting to workbench,
attach the pedestal using the provided wing
screws, and use appropriate fasteners (not
provided) to secure to bench.
NOTE: When mounting in fixed position, install
guard plate, shown in Figure 8-3. When using as
portable machine, leave guard plate off.
6.0 Electrical connections
Electrical connections should
be made by a qualified electrician in
compliance with all relevant codes. Failure to
comply may cause serious injury.
The JB-10 series Beveling Machine is prewired for
single phase, 115V power. It is provided with a
plug designed for use on a circuit with a grounded
outlet that looks like the one pictured in Figure 6-1.
Before connecting to power source, be sure switch
is in off position.
It is recommended that the Plate Beveling Machine
be connected to a dedicated 15 amp circuit with
circuit breaker or fuse. If fuses are used, they
should be time-delay fuse marked “D”. Local
codes take precedence over recommendations.
6.1 GROUNDING INSTRUCTIONS
1. All Grounded, Cord-connected Tools:
This machine must be grounded. In the event of a
malfunction or breakdown, grounding provides a
path of least resistance for electric current to
reduce the risk of electric shock. This tool is
equipped with an electric cord having an
equipment-grounding conductor and a grounding
plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a
qualified electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding conductor. If repair or
replacement of the electric cord or plug is
necessary, do not connect the equipment-
grounding conductor to a live terminal.
Check with a qualified
electrician or service personnel if the
grounding instructions are not completely
understood, or if in doubt as to whether the
tool is properly grounded. Failure to comply
may cause serious or fatal injury.
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept
the tool's plug.
Repair or replace damaged or worn cord
immediately.
2. Grounded, cord-connected tools intended for
use on a supply circuit having a nominal rating less
than 150 volts:
This tool is intended for use on a circuit that has an
outlet that looks like the one illustrated in Figure 6-
1.
Figure 6-1
Loading ...
Loading ...
Loading ...