37
INSTALLATION
Installation Test (Duct Check)
Once you have completed the installation of the
dryer, use this test to make sure the condition of the
exhaust system is adequate for proper operation of
the dryer. This test should be performed to alert you
to any serious problems in the exhaust system of
your home.
Your dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces
energy use.
NOTE
The dryer should be cool before starting this test.
If the dryer was warmed up during installation, run
the AIR DRY cycle for a few minutes to reduce
the interior temperature.
To activate the installation test:
1
Remove the drying rack and literature, and
then close the door.
Do not load anything in the drum for this test, as
in may affect the accuracy of the results.
2
After you are pressed of Power button, you
will press and hold the Temp. and Signal
buttons in 3 seconds.
This button sequence activates the installation
test. The code
will display if the activation
is successful.
(For Models: DLE7**0* / DLG7**1*)
Press and hold the POWER, Temp., and
Wrinkle Care buttons until
and a usage
count alternate in the display. (The usage count
indicates the number of cycles run with no load
during the last 5 cycles.)
3
Press the START/PAUSE button.
The dryer will start the test, which will last about
2 minutes. The heat will be turned on and the
temperatures in the drum will be measured.
4
Check the display for results.
During the test cycle, monitor the Flow Sense™
display on the control panel. If no bars are
displayed(or LED is not turned on), when the
cycle ends, the exhaust system is adequate. If
the exhaust system is severely restricted, the
display will show four bars. Other problems may
also be shown with error codes. Refer to the
next page for error code details and solutions.
NO BARS:
OK
FOUR BARS:
RESTRICTED
LED; turned on :
RESTRICTED
Four bars(or Flow Sense™) indicates that the
exhaust system is severely restricted. Have the
system checked immediately, as performance
will be poor.
5
End of cycle.
At the end of the test cycle,
or will
display. The test cycle will end and the dryer will
shut off automatically after a short delay.
Check the error code before you call for service
Error
Code
Possible
Causes
Solutions
tE1 or
tE2
Temperature
sensor failure.
Turn off the dryer and
call for service.
HS
Humidity
sensor failure.
Turn off the dryer and
call for service.