HOW TO DRAIN THE INTERNAL WATER TANK
*You will need a small pan, approximately 1” high to catch the water coming out of the water tank. Once
the water tank is empty, the unit will resume operation within a few minutes.
1. Do not move the unit when the water container is full (water will spill out).
2. Place a small pan under the condensation drain hole on the bottom side of the unit.
3. Remove the drain plug from the condensation drain hole. The condensate water will drain out automati-
cally.
4. When the drain pan is full, install the drain plug back onto the condensation drain hole to stop the water
flow.
5. Empty the drain pan.
6. Repeat steps 2-5 until all the water is emptied.
NOTE: Once the condensate tank has been emptied, firmly press the drain plug back onto the condensa-
tion drain hole (Fig 15.1). It is not advised to use continuous drainage when the room temperature is higher
than 90˚F.
NOTE: You may also use enclosed Optional Drain Tube to facilitate the draining process, make sure to re-
plug the Drain Stopper once the condensation tank has been emptied (Fig 15.2).
Fig 15.1
Fig 15.2