Indesit IS67G1PMW/UK Gas freestanding 60cm cooker

instruction for use - Page 8

For IS67G1PMW/UK.

PDF File Manual, 20 pages, Read Online | Download pdf file

IS67G1PMW/UK photo
Loading ...
Loading ...
Loading ...
Gas connection
The cooker should be connected to the gas-supply by a gas safe registered
installer. Connection of the appliance to the gas mains or liquid gas must be
carried out according to the prescribed regulation in force, and only after it
is ascertained that it is adaptable to the type of gas to be used. If not, follow
the instructions indicated in the paragraph headed "Adaptation to different
gas types". In the case of connection to liquid gas, by tank, use pressure
regulators that conform to the regulation in force. The gas supply must be
connected to the left of the appliance. Be sure that the hose does not pass
through the rear of the cooker touching hot parts.
Make sure the supply pressure conforms with the values shown in the table
entitled "Characteristics of the burners and nozzles".
When the cooker is installed between cabinets (recessed), the gas
connection must be effected by an approved flexible hose with bayonet
fitting (BS 669 or EN 14800). The gas inlet for the cookers is a threaded G 1/2
gas female fitting.
Connecting the gas supply
To make the connection, a flexible hose should be used corresponding to
the current gas regulations which are:
the hose must never be at any point in its length in contact with the "hot"
parts of the cooker;
the hose must never be longer than 1,5 meter;
the hose must not be subject to any tension or torsional stress and it
must not have any excessively narrow curves or bottlenecks;
the hose must be easy to inspect along its entire length to check its
condition;
the hose must always be in good condition, never attempt to repair.
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners
off their seats.
2. Unscrew the nozzles using a 7mm socket
spanner (see figure A) and replace them
with nozzles suited to the new type of gas
(see Burner and nozzle specifications table).
Adapting the cooker to different types of gas:
It is possible to adapt the appliance to a type of gas other than
the default type (this is indicated on the rating label on the cover).
Adapting the hobs:
3. Replace all the components by following the above instructions in reverse.
Adapting the hob burner's minimum setting::
1. Light the burner (see Start-up and Use
).
2. Turn the knob to the minimum position (MIN) after it has been
in the maximum position (MAX) for approximately 10 minutes.
3. Remove the knob.
4. Tighten or loosen the adjustment screws on the outside of the
thermostat pin (see figure B) until the flame is small but steady.
! If the appliance is connected to liquid gas, the bypass screw
must be adjusted to minimum.
5. Turn the knob from the MAX position to the MIN position
quickly or open and shut the oven door, making sure that the
burner is not extinguished.
Adapting the oven
Replacing the oven burner nozzle:
1. Remove the oven compartment.
2. Slide out the protection panel A (see
figure 1).
3. Remove the oven burner after unscrewing
the screws V (see figure 2). The whole
operation will be made easier if the oven
door is removed.
4. Unscrew the nozzle (see figure 3) using 7
mm socket spanner and replace it with a
new nozzle that is suited to the new type
of gas (see Burner and nozzle
specifications table).
Adjusting the gas oven burner’s
minimum setting:
A
V
Adapting the grill
Replacing the grill burner nozzle:
1. Remove the grill burner after loosening
screw V (see figure 4).
2. Unscrew the grill burner nozzle using a 7
mm socket spanner X (see figure 5) and
replace it with a new nozzle that is suited
to the new type of gas (see Burner and
nozzle specifications table)
V
X
! Be careful of the spark plug wires and the thermocouple
tubes.
! The oven and grill burners do not require primary air
adjustment.
! After adjusting the appliance so it may be used with a
different type of gas, replace the old rating label with a new
one that corresponds to the new type of gas (these labels are
available from Authorised Technical Assistance Centres).
! Should the gas pressure used be different (or vary slightly)
from the recommended pressure, a suitable pressure
regulator must be fitted to the inlet hose in
accordance with
current national regulations relating to “regulators for
channelled gas”.
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory
screw, which is positioned inside or next to the
tap pin (see figure B), until the flame is small but
steady. If the appliance is connected to a liquid
gas supply, the bypass screw must be set to a
minimum.
3. While the burner is alight, quickly change the position of the knob from
minimum to maximum and vice versa several times, checking that the
flame is not extinguished.
Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
After adjusting the appliance so it may be used with a different type of gas,
replace the old rating label with anew one which corresponds to the new
type of gas (these labels are available from Authorized Technical
Assistance Centers).
Should the gas pressure used be different (or vary slightly) from the
recommended pressure, a suitable pressure regulator must be fitted to the
inlet hose in accordance with current standards EN 88-1 and EN 88-2
relating to "regulators for channeled gas".
Fig. 4
Fig.5
Fig. 1
Fig. 2
Fig. 3
8
Fig. A
Fig.B
Loading ...
Loading ...
Loading ...